Repair Request Ms. XXXXXX
Drywall damage visible in the entryway likely due to wall anchors failing.
Entryway
Contact a qualified drywall contractor.
Air gap exists at the base of the French door which could lead to energy loss and pest infestation. Recommend handyman or door contractor evaluate.
Main Entrance
The patio door from the living room to the pool area was difficult to slide open and shut.
Contact a qualified door repair/installation contractor.
The fire door from the living quarters to the garage lacks a self-closing mechanism. No fire rating sticker present so unable to verify it meets minimum requirements.
Contact a qualified door repair/installation contractor.
One or more windows appears to have general damage, but are operational in the East middle bedroom. There is staining on the glazing and the screen is damaged. Recommend a window professional clean, lubricate & adjust as necessary.
Contact a qualified window repair/installation contractor.
Rectified by removal of contents
Water heater is improperly installed or in a dangerous location. Recommend qualified plumber evaluate & repair/relocate.
Combustible contents in close proximity to gas and ignition sources
Gas utility should rectify for free
Gas leak detected at the gas meter with hydrocarbon detection device. Have evaluated by the utility company or a qualified plumbing contractor inspect immediately.
Gas Meter
Contact your local utility company
Rectified by removal of contents
I observed inadequate workspace at the electrical panel. Inspection restriction. This makes accessing the electrical panel disconnects and components difficult.
A clear working space must be provided and maintained for safe access. At least 3 feet deep clear space should be in front of the equipment, 30 inches wide, and 6 feet 6 inches of headroom.
Contact a qualified professional.
One or more receptacles are missing a cover plate. This causes short and shock risk. Recommend installation of plates.
$35 per unit times 8 units
The Smoke Detectors were over 10 years old and should be replaced.
Recommended DIY Project
One or more heating elements did not heat up when turned on. Recommend qualified professional evaluate & repair.
Here is a DIY resource on possible solutions.
Range was not fastened to the floor. This poses a safety hazard to children. Recommend a qualified contractor secure range so it can't tip.
Bathroom countertop was missing sufficient caulk/sealant at the wall. This can lead to water damage. Recommend adding sealant at sides and corners where counters touch walls.
I observed indications of a damaged exhaust pipe of the clothes dryer.
Recommended DIY Project
The seal from the duct to the air handler is separating. Recommend evaluation by a qualified HVAC technician.
Garage
Contact a qualified HVAC professional.
Thermostat was loose on the wall. Recommend repair or replacement.
The System is in need of cleaning and proper maintenance.
We recommend inquiring about the maintenance history of the equipment, and/or consult an HVAC contractor to evaluate the systems and determine if deferred maintenance caused any issues toward the equipment's longevity.
Contact a qualified professional.
Recheck and seal ducts as needed in attic
There are disconnected joints in the ductwork, resulting in significant energy loss and localized condensation/mold. Recommend licensed HVAC contractor repair or replace.
above northeast bedroom
Contact a qualified HVAC professional.
Siding or exterior cladding showed cracking in one or more places. This is a result of temperature changes, and typical as homes with stucco age. Recommend monitoring.
Paver company needs to be brought in to remove/reset
I observed a trip hazard at the walkway to the swimming pool. This condition is a safety concern.
Correction and further evaluation are recommended. The correction may require removal/replacement of the displaced sections.
Contact a qualified professional.
Tree debris observed on roof. This can cause improper drainage to gutters and downspouts. Recommend clearing debris.
Captured in previous comment
Trees observed overhanging the roof. This can cause damage to the roof and prevent proper drainage. Recommend a qualified tree service trim to allow for proper drainage.
Clean out and re-connect
Gutter downspout not connected to drainage line. This will allow rainwater to pool in the area of the pool enclosure entrance.
Contact a qualified professional.
Concrete needs to be cut away to allow drainage
Channel drain terminates into the pool cage framing, which constitutes a construction defect.
Contact a qualified professional.
To service all gutters of facility
Debris has accumulated in the gutters. Recommend cleaning to facilitate water flow.
Here is a DIY resource for cleaning your gutters.
One or more downspouts drain too close to the home's foundation. This can result in excessive moisture in the soil at the foundation, which can lead to foundation/structural movement. Recommend a qualified contractor adjust downspout extensions to drain at least 6 feet from the foundation.
Here is a helpful DIY link and video on draining water flow away from your house.