633 Safstrom Dr
Idaho Falls, ID 83401
03/30/2021 9:00 am

28
Low priority
20
Medium priority
1
High priority

Thank you for choosing Idaho Elite Inspection Team.

Please carefully read through the entire inspection report. We are happy to assist with additional question you may have. 

This report is based on a visual inspection of the building at the time and date of the inspection. Given the limited time allowed for an inspection, please do not expect that every concern or issue will be noted. Conditions of an occupied home can change after an inspection or sellers items may obscure our view of other defects. We strongly recommend that you and/or your representative carry out a final walk through immediately before closing to check the condition of the property. 

Listed with most items of concern is a recommendation for a trade specialist. For your safety and liability, these concerns should be evaluated by the appropriate contractors prior to closing. Further recommendations may be given by a specialist. Lastly, we recommend obtaining at a minimum a full 1 year warranty as additional items for repair are likely to come about within that time. Here is a video walk-through on How to Read Your Inspection Report.

We have found a number of items that we recommend further evaluation or repair. Please visit our Trusted Resources for our list of recommended vendors who can assist with repairs and other services.


1 - Positive Attributes of the Home

Roof
Metal Roof
Siding
Brick

2 - Inspection Details

Start Time
9am
In Attendance
Inspector
Occupancy
Occupied
Style
Multi-level
Weather Conditions
Clear
Year Built
1957
Temperature
20-30 degrees
Type of Building
Single Family
The images here are the directional locations of the home used throughout the report. Ensure you get yourself orientated to what direction the house is situated in order to better follow along.
Older home advisory

This home is considered an older home, built in an era when building standards were not at today's standards. As further advisory to the below inspection findings, older homes tend to have quirks or other deficiencies about them that may not be visible during a home inspection. These items may included; under ground oil tanks, hidden knob and tube wiring, substandard insulation, galvanized plumbing, multi-layered roofs, etc. Additionally, hidden items and structures may not have been built to modern standards and may not have been visible at the time of inspection. 

3 - Exterior

Driveway, Walkways & Patio: Driveway Acceptable

The driveway is in acceptable condition.

Driveway, Walkways & Patio: Walkway Acceptable

The walkways are in acceptable condition.

Exterior Siding Notes: Siding Type
Brick, Wooden Siding
Doorbell: Acceptable

The doorbell is functional and works on demand.

Fences & Gates: Acceptable

The fences were in acceptable condition.

Fences & Gates: Gates in acceptable condition

The gates were in acceptable condition.

General Comments: Exterior comments

It is important to maintain a property, including painting or sealing walkways, decks, and other hard surfaces, and it is particularly important to keep the house walls sealed, which provide the only barrier against deterioration. Unsealed cracks around windows, doors, and thresholds can permit moisture intrusion, which is the principle cause of the deterioration of any surface. Unfortunately, the evidence of such intrusion may only be obvious when it is raining. We have discovered leaking windows while it was raining that may not have been otherwise apparent. Regardless, there are many styles of windows but only two basic types, single and dual-glazed. Dual-glazed windows are superior because they provide a thermal, as well as an acoustical barrier. However, the hermetic seals on these windows can fail at any time and cause condensation to form between the panes. Unfortunately, this is not always apparent, which is why we disclaim an evaluation of hermetic seals. Nevertheless, in accordance with industry standards, we test a representative number of unobstructed windows and ensure that at least one window in every bedroom is operable and facilitates an emergency exit.

Grading & Drainage: General Grading Comments

Water can be destructive and foster conditions that are disastrous to health. For this reason, the ideal property will have soils that slope away from the residence and the interior floors will be several inches higher than the exterior grade. Also, the residence will have roof gutters and downspouts that discharge into area drains with catch basins that carry water away to hard surfaces. However, we cannot guarantee the condition of any subterranean drainage system, but if a property does not meet this ideal, or if any portion of the interior floor is below the exterior grade, we cannot endorse it and recommend that you consult with a grading and drainage contractor, even though there may not be any evidence of moisture intrusion. The sellers or occupants will obviously have a more intimate knowledge of the site than we could possibly hope to have during our limited visit, however, we have confirmed moisture intrusion in residences when it was raining that would not have been apparent otherwise. Also, in conjunction with the cellulose material found in most modern homes, moisture can facilitate the growth of biological organisms that can compromise building materials and produce mold-like substances that can have an adverse affect on health.

Exterior Siding Notes: Acceptable

The exterior house wall finish is generally in acceptable condition. Any exceptions will be noted below.

Foundation as Viewed from the Exterior: Exterior View

The foundation was in acceptable condition as viewed from the exterior. Any exceptions will be noted.

Fascia, Trim & Eaves: Acceptable

The fascia boards, trim and eaves are in acceptable condition. Any exceptions will be noted below.

Exterior Plumbing: Hose bibs functional

The hose bibs that were found and accessible were functional. Any exceptions will be noted.

Downspouts: Acceptable

The downspouts appear to be in acceptable condition.  Any exceptions will be noted below. We recommend downspouts always drain away from the structure and foundation.

Exterior Doors: Exterior doors acceptable

The exterior doors were in acceptable condition. Any exceptions will be noted.

Lights: Acceptable

The lights outside the doors of the residence are functional. Any sensor or light sensitive fixture lights were not tested.

Exterior Plumbing: Sprinkler system not tested

There may be an irrigation system installed on or around the property. Unless otherwise noted, this system was not tested during our inspection due to it being beyond the scope of our inspection.
We recommend consulting the homeowner or an irrigation specialist for a demonstration and inspection of this system. Any maintenance or repairs should be performed if warranted.

This inspection is not intended to address or include any geological conditions or site stability information. For information concerning these conditions a geologist or soils engineer should be consulted. Any reference to grade is limited to only areas around the exterior of the exposed foundation or exterior walls. This inspection is visual in nature and does not attempt to determine drainage performance of the site or the condition of any underground piping, including municipal water and sewer service piping or septic systems. 

When decks and porches are built close to the ground where no viewing or access is possible, we cannot make accurate opinions. These areas as well as others that are too low to enter, or in some other manner not accessible, are excluded from the inspection and are not addressed in this report. We routinely recommend that inquiry be made with the seller about knowledge of conditions, repairs are usually noted in the form seventeen.

Our inspection of the Exterior grounds includes the surface drainage, grading, some fencing, gates, sidewalks, patios, driveways, and retaining walls adjacent to the structure. The inspection of the exterior of the building includes the cladding, trim, eaves, fascias, decks, porches, downspouts, railings, doors, windows and flashings. Areas hidden from view by finished walls or stored items can not be judged and are not a part of this inspection. Minor cracks are typical in many foundations and most do not represent a structural problem. If major cracks are present along with rotation, we routinely recommend further evaluation be made by a qualified professional structural engineer. All exterior grades should allow for surface and roof water to flow away from the foundation. All concrete slabs experience some degree of cracking due to shrinkage in the drying process or minor settlement.  

Where deck carpeting, stacked firewood, excessive vegetation, soil and other coverings are installed, the materials or their nature of construction and condition of the underneath cannot be determined. All items listed are inspected for their proper function, poor installation, excessive wear and general state of repair.

$
Credit
Comment
3.1.1 - General Comments

Debris in window well

Debris was observed in the window wells recommend removing to prevent moisture intrusion 

Qualified Professional
$
Credit
Comment
3.2.1 - Driveway, Walkways & Patio

Moderate Cracks in Driveway

There are a few cracks in the driveway which is mostly cosmetic, but you may want to view for yourself and repair as necessary.

Monitor
$
Credit
Comment
3.4.1 - Grading & Drainage

Grading and drainage is negative or neutral

Grading and drainage is either negative or neutral adjacent to the residence and moisture intrusion will remain a possibility. The soil or the hard surfaces should slope away from the residence to a distance of at least six feet to keep moisture away from the footings. We can elaborate on this issue, but you should seek a second opinion from a geologist or grading and drainage contractor.

Monitor
$
Credit
Comment
3.5.1 - Exterior Siding Notes

Seal penetations/gaps

Gaps and/or holes were observed on one or more sides in the siding around plumbing, gas, cable, wiring and/or other penetrations. We advise that all the holes and the gaps be caulked and/or sealed to prevent moisture and/or pest intrusion.

Qualified Professional
$
Credit
Comment
3.5.2 - Exterior Siding Notes

Mortar deteriorated or missing

Deteriorated or missing mortar was observed on one or more locations along the front entry/exterior. Recommend sealing gaps

Qualified Professional
$
Credit
Comment
3.6.1 - Foundation as Viewed from the Exterior

Small cracks

Hairline and/or small cracks within normal tolerances, were visible. This type of cracking is often a result of shrinkage of materials and/or minor settlement and usually does not affect the performance of the foundation.

Monitor
$
Credit
Comment
3.10.1 - Exterior Doors

Hollow core exterior door
Basement Walkout/garage entry

The exterior door is hollow core rather than a solid core entry door. We recommend a more sturdy exterior door be installed.

Qualified Professional
$
Credit
Comment
3.13.1 - Lights

Light bulbs missing or burnt out

Some lights around the residence did not have light bulbs or the bulbs were burnt out. Recommend replacing bulbs and testing.

Qualified Professional
$
Credit
Comment
3.14.1 - Outlets, Electrical Observations

Hot neutral reverse

An outlet has reversed polarity and should be serviced.

To learn more why this is dangerous CLICK HERE.

 

Electrical Contractor

4 - Roof

Metal Roof: Metal roof is in acceptable condition

The metal roof is in acceptable condition. 

Roof Electrical : Accept

The electrical strike and mast were in acceptable condition.

Chimney On Roof & Photo: Chimney Photo
Roof Electrical : Electrical Strike Photo
Method of Evaluation & Photos: Method of Evaluation & Photos
Walking on its surface
Vents & Flashings: Acceptable

The roof flashings and vents are in acceptable condition where viewed. They appear to consist of metal flashing around roof penetrations and in valleys.

Gutters & Drainage: Acceptable

The gutters appear to be in acceptable condition.  Any exceptions will be noted below.

Chimney On Roof & Photo: Acceptable

The the chimney above the roof is in acceptable condition. Any exceptions will be noted.

The inspection of the roof system includes a visual examination of the surface materials, connections, penetrations and roof drainage systems. We examine the roofing material for damage and deterioration. We examine the roof system for possible leaks, damage and conditions that suggest limited remaining service life. We may offer opinions concerning repair and/or replacement if warranted. Opinions stated herein concerning the roofing material are based on the general condition of the roof system as evidence by our visual inspection.  

These do not constitute a warranty that the roof is or will remain, free of leaks. All roofing systems require annual maintenance. Failure to perform routine maintenance will usually result in leaks and accelerated deterioration of the roof covering and flashings. When provided, our estimates of the roof's life expectancy are based on the assumption that the roof will be properly maintained during that period.

This report is issued in consideration a foregoing disclaimer in the future. The only way to determine whether a roof is absolutely water tight is to observe it during a prolonged rainfall. Many times, this situation is not present during the inspection and we cannot confirm this condition. We suggest that a annual inspection of the Attic area be performed where accessible to identify if any leaks are evident.


$
Credit
Comment
4.2.1 - Metal Roof

Loose Fasteners

Several loose fasteners were observed throughout the roof. This may allow for loose sheets flashing and potential for leaks. Recommend that a roofing contractor a body weight and make necessary repairs.

Roofing Professional
$
Credit
Comment
4.3.1 - General Observations

Overhanging branches

Trees near the dwelling have overhanging branches and/or branches in contact with the roof surface, which may cause damage to the roof surface. This condition may also cause the obstruction of roof water runoff and is a access for rodents, animals and carpenter ants. All overhanging or touching branches in contact of the roof surface should be trimmed to eliminate this condition.

Qualified Professional
$
Credit
Comment
4.5.1 - Gutters & Drainage

The gutters need to be cleaned and serviced to drain properly

The gutters need to be cleaned and serviced to drain properly. However, without water in them it is difficult to judge whether they are correctly pitched to direct water into the downspouts, but they should function as they were intended.

Roofing Professional
$
Credit
Comment
4.6.1 - Chimney On Roof & Photo

Loose Bricks

There were loose bricks observed on the chimney. These should be reset and secured to ensure proper functioning of the chimney.

Qualified Professional
$
Credit
Comment
4.6.2 - Chimney On Roof & Photo

No spark arrestor or rain cap

The chimney does not have a spark arrestor or rain cap as recommended. This will help prevent pests or debris from falling into the flue and causing an obstruction or damage.

Handyman
$
Credit
Comment
4.6.3 - Chimney On Roof & Photo

Crown deteriorated

The crown, which is designed to seal the chimney wall and to shed rainwater, is washed out or deteriorated and should be repaired or replaced.

Masonry, Concrete, Brick & Stone
$
Credit
Comment
4.6.4 - Chimney On Roof & Photo

Flashing seal

Flashing around chimney requires additional sealant

Qualified Professional
$
Credit
Comment
4.7.1 - Roof Electrical

No Drip Loop

The electrical service entrance does not have a drip Loop. This may allow water to drip down the wire and enter the masked. Recommend a proper drip Loop per industry standards.

5 - Garage(s)

Automatic Opener: Acceptable

The automatic garage door opener is acceptable.

Automatic Opener: Safety lights - Acceptable

The garage door safety lights open the door when obstructed.

Garage Door & Hardware: Acceptable

The sectional garage door and its hardware are functional.

Firewall Separation: Acceptable

The firewall separating the garage from the residence is functional.

Walls and Ceiling: Acceptable

The visible walls and ceiling are in acceptable condition.

Windows: Acceptable
The windows are functional.
Outlets, Electrical Observations: Acceptable

The outlets were in acceptable condition.

Picture and size of garage: Picture and size of garage
Double Car Garage

The garage and its components were evaluated.

Slab Floor: Acceptable

The visable garage slab floor is in acceptable condition. Small cracks are common and result as a consequence of the curing process, seismic activity, common settling, or the presence expansive soils, but are not structurally threatening.

Parking Space: Check parking space to accommodate your vehicles

It would be prudent for you to see that the parking space is adequate to accommodate your vehicles.

Garage Side Door: Acceptable

The side door is functional. A solid security type door. Noted a deadbolt, door sweep, threshold and adequate weather stripping.

The Garage is inspected as best as possible, but can be limited due to parked cars or personal stored items. Due to this area be cluttered or areas being inaccessible, it is common for sections that cannot not be fully inspected or items identified during our limited inspection. We suggest that a walk-through be performed once the home is vacant. If this is a new construction inspection or vacant home this area will be inspected thoroughly. Determining the heat resistance rating of fire walls and doors is beyond the scope of this inspection. Flammable materials should not be stored within the Garage area if possible.

$
Credit
Comment
5.4.1 - Entry Door Into the House

Home entry not self closing

The house garage entry door is functional but does not self-close. This may not have been required when the house was built and you may elect to have self closing hinges installed for modern fire safety.

Handyman
$
Credit
Comment
5.7.1 - Garage Side Door

Door striker plate

The entry door striker plate needs to be adjusted for the striker pin to engage.
$
Credit
Comment
5.7.2 - Garage Side Door

Weathered Door

The side door to the garage is weathered. We recommend maintenance or replacement.

Qualified Professional
$
Credit
Comment
5.8.1 - Firewall Separation

No firewall separation between the garage and residence

There is no firewall separation between the garage and the residence, and one is mandated and should be installed.
Qualified Professional

6 - Main Electrical Panel

Service Entrance: Main Lines
Underground
Service Entrance: Main Lines Acceptable

The electrical service entrances are acceptable.

Panel Cover Condition: Acceptable

The electrical panel cover is in acceptable condition.

Wiring Notes: Electrical Service Conductors
Copper, 120/240 volt
Wiring Notes: Acceptable

The visible portions of the wiring have no deficiencies.

Circuit Breakers: Acceptable

There are no visible deficiencies with the circuit breakers.

Panel Size, Location & Photo: Panel Amps, Location and Picture
100 Amp, Garage
Panel Size, Location & Photo: Earth Ground
Earth Ground Rod

The main panel groundingwas observed and found to be in good repair andof adequate function at the time of the inspection.

Main Panel Notes: Acceptable

The panel and its components have no visible deficiencies. Any exceptions will be noted below.

Our examination of the electrical system includes a visual examination of the exposed and accessible branch circuits, wiring, service panel, over current protection devices, lighting fixtures, switches, and receptacles. Service equipment, proper grounding, wiring methods and bonding are focal points. We inspect for adverse conditions such as improper installation of aluminum wiring, lack of grounding and bonding, over-fusing, exposed wiring, open-air wire splices, reverse polarity and defective GFCI's. The hidden nature of the electrical wiring prevents inspection of every length of wire or their connections. Telephone, video, cable, audio, security systems and other low voltage systems were not included in this inspection unless specifically noted. We recommend you have the seller or a specialist demonstrate the serviceability or locations of these systems to you if necessary.

Any electrical repairs attempted by anyone other than a licensed electrician should be approached with caution. The power to the entire house should be turned off prior to beginning any repair efforts, no matter how trivial the repair may seem. Aluminum wiring requires periodic inspection and maintenance by a licensed electrician. Operation of time clock motors is not verified. Inoperative light fixtures often lack bulbs or have dead bulbs installed. Light bulbs are not changed during the inspection, due to time constraints. Smoke Alarms should be installed within 15 feet of all Bedroom doors and in Bedrooms. These units should be tested monthly.

7 - Cooling System

Condensing Coil (outside): Acceptable

The condensing coil(s) appeared to be in acceptable condition. 

Refrigerant Lines: Acceptable
The refrigerant lines are in acceptable condition where viewed.
Photo
Condensing Coil Disconnect: Acceptable
The electrical disconnect(s) at the condensing coils are present and appear functional; however they were not activated or used at the time of inspection.

A central cooling system consists of the cooling equipment, which is a means of distribution, operation and safety controls. These items were examined for proper function, unusual wear and general state of repair. Detailed testing of the mechanical components of the cooling system or predicting their service life requires specialized equipment and training and is beyond the scope of a home inspection. Cleaners, humidifiers and de-humidifiers are beyond the scope of this inspection. The inspector does not perform pressure tests on coolant systems, therefore no representation is made regarding coolant charge or line integrity. Subjective judgment of system capacity is not a part of the inspection. If the air conditioning system was not tested because the outside temperature was too cold for safe operation, this fact will be so noted in the report that follows. With any mechanical system, we recommend the employment of an air conditioning technician to conduct a regular service and inspect all air conditioning equipment.

8 - Heating System

General Notes & Photos: Energy Source/Type
Natural Gas
Furnace Notes: Year
2004
Furnace Notes: Power Source/Type
Natural Gas
Furnace Notes: Limit switches

The safety switches for the gas furnace were acceptable 

Vent Pipe: Acceptable

The gas furnace vent pipe is in acceptable condition.

Thermostats: Acceptable

The thermostats were functional at the time of the inspection

Registers: Acceptable

The air supply registers are reasonably clean and appear functional.

General Notes & Photos: Equipment Photos/Video
General Notes & Photos: Disclaimer

The components of most heating and air-conditioning systems have a design-life ranging from ten to twenty years, but can fail prematurely with poor maintenance, which is why we apprise you of their age whenever possible. We test and evaluate them in accordance with the standards of practice, which means that we do not dismantle and inspect the concealed portions of evaporator and condensing coils, the heat exchanger, which is also known as the firebox, electronic air-cleaners, humidifiers, ducts and in-line duct-motors or dampers. We perform a conscientious evaluation of both systems, but we are not specialists. However, even the most modern heating systems can produce carbon monoxide, which in a sealed or poorly ventilated room can result in sickness, debilitating injury, and even death. Therefore, in accordance with the terms of our contract, it is essential that any recommendations that we make for service or a second opinion be scheduled before the close of escrow, or within the inspection perioed if possible, because a specialist could reveal additional defects or recommend further upgrades that could affect your evaluation of the property, and our service does not include any form of warranty or guarantee. Having the heating and cooling system fully evaluated by a qualified HVAC technician before the close of escrow and at least annually is recommended, regardless of its condition.

Furnace Notes: Acceptable

The furnace was functional and responds when prompted at it's thermostat. I recommend further review from a qualified HVAC technician for more information or a detailed evaluation, at least before the close of escrow, or as you feel necessary.

Furnace Notes: Thermocouple ok
The thermocouple is a gas furnace component located near the pilot light burner. It is a safety device that shuts off the gas if the pilot light goes out or the electric igniter fails. This was viewed on the furnace and appears acceptable. However only a specialist can deturmine its functionality.
Gas Valve & Connector: Acceptable

The gas valve and connector are in acceptable, visible condition, however the valve itself was not turned or operated.

Combustion-Air Vents: Acceptable

The combustion-air vents appear to be adequate to support complete combustion.

Ducting: Acceptable

The easily visible ducts have no visible deficiencies. Any exceptions will be noted. 

Return-Air Compartment: Acceptable

The return-air compartments are in acceptable condition. I recommend changing the filters every 30 - 60 days or as required by the manufacturer. Any interior or internal HVAC system filters were not evaluated as part of this inspection. This includes any filters located within the interior air handler or furnace unit where located in the attic, garage or a closet etc.

Our examination of the heating system includes a visual examination of the exposed and accessible heating equipment, thermostat, safety controls, venting and the means of air distribution. Our inspection of the heating system includes activating the heating system via the thermostat and a visual examination of the accessible components listed below.

These items are examined for proper function, excessive or unusual wear and general state of repair. Heat exchangers are inaccessible by design, and are not part of the Washington standards of practice. They must be completely removed from the furnace to be fully evaluated. Our inspection does not include disassembly of the furnace. The inspector cannot light pilot lights due to the liability. Safety devices are not tested by the inspector. To obtain maximum efficiency and reliability from your heating system, we recommend annual servicing and inspections by a qualified heating specialist.

Determining the condition of oil tanks, whether exposed or buried, is beyond the scope of this inspection. Leaking oil tanks represent an environmental hazard which is sometimes a costly condition to address.

9 - Water Heater & Plumbing

Water Heating System: Energy Source/Type
Natural Gas
Water Heating System: Year
2012
Water Heating System: Location
Basement
Water Heating System: Capacity
40
Main Water Shut-Off, Distribution & Supply: Water Meter Location
Front
Main Water Shut-Off, Distribution & Supply: Water Supply Material To House
Copper
Drain, Waste, & Vent Systems: Waste pipe Material
Iron, ABS, Galvanize
Gas Components: Main Gas Shut-off Location
Meter
Main Water Shut-Off, Distribution & Supply: Main Water Shut off Location
Basement
Water Heating System: Manufacturer and picture
Bradford & White

I recommend flushing & servicing your water heater tank annually for optimal performance. Water temperature should be set to at least 120 degrees F to kill microbes and no higher than 130 degrees F to prevent scalding.

Here is a nice maintenance guide from Lowe's to help.

Main Water Shut-Off, Distribution & Supply: Plumbing acceptable

The plumbing was generally in acceptable condition. Any exceptions will be noted low.

Main Water Shut-Off, Distribution & Supply: Water Distribution Material
Galvanized

A representative amount of the plumbing distribution system was observed and found to be in good repair.

Drain, Waste, & Vent Systems: Acceptable

Based on industry recommended water tests, the drainpipes are functional and acceptable at this time and functional drainage was noted. However, only a video-scan of the main drainpipe could confirm its actual condition which is beyond the scope of a general home inspection. Any exceptions will be noted below.

Drain, Waste, & Vent Systems: Side Sewer Notes

For a full evaluation of the waste line, we recommend that a sewer scope be completed.

Gas Components: Gas Supply Pipes-Acceptable

The visible portions of the gas pipes and their supports appear to be in acceptable condition.

Water Softener: Water softner inspected For leaks only

We inspected the soft water system for leaks only you should ask the sellers for documentation and its functionality.

Please visit our Trusted Resources page for a list of contractors who can assist with this.

Water Softener: Soft water or reverse osmosis not inspected

Soft water and reverse osmosis not evaluated

Our inspection of the water heater includes a visual examination of the accessible portions of the tank, gas, electrical and/or water connections, venting and safety valves. These items are examined for proper function, excessive or unusual wear, leakage and general state of repair. 

Our Inspection of the plumbing system includes a visual examination of the exposed portions of the domestic water supply, drain waste, vent, gas lines, faucets, fixtures, valves, drains, traps, exposed pipes and fittings. These items are examined for proper function, excessive or unusual wear, leakage and general state of repair. The hidden nature of piping prevents inspection of every pipe and joint connection, especially in walls, floors and ceiling voids. A sewer lateral test is necessary to determine the condition of the underground sewer lines is beyond the scope of this inspection.  

Our review of the plumbing system does not include landscape irrigation systems, water wells, on site and/or private water supply systems, off site community water supply systems, or private (septic) waste disposal systems unless specifically noted. Review of these systems could be performed by qualified specialists prior to closing of escrow.

$
Credit
Comment
9.1.1 - Water Heating System

Seismic Straps - Missing/Insufficient

The hot water heater was missing seismic straps or was insufficiently anchored. Recommend two straps to properly secure water heater in the case of an earthquake.

Please visit our Trusted Resources page for a list of contractors who can assist with this.

Qualified Professional
$
Credit
Comment
9.1.2 - Water Heating System

Floor Contact

The water heater is sitting directly on the concrete floor. We recommend elevating to prevent rusting and corrosion. 

Qualified Professional
$
Credit
Comment
9.1.3 - Water Heating System

Needs drip loop or leg.

The flexible gas feed line to the water heater doesn't have a drip loop or drip leg to catch debris in the gas line. I recommend further evaluation from a qualified technician or plumber for service if necessary .
Plumbing Contractor

10 - Kitchen

Sink and Faucet: Acceptable

The kitchen sink and faucet are functional.

Trap and Drain: Acceptable

The kitchen trap and drain are functional. No leaking was noted.

Countertop: Acceptable

The visible areas of the kitchen countertops were functional.

Exhaust Fan Notes: Acceptable
Vents Internally
The kitchen exhaust fan was functional.
Walls and Ceiling: Acceptable

The walls and ceiling are textured drywall and in acceptable condition.

Cabinets: Acceptable

The cabinets are functional, and do not have any significant damage.

Lights, Wall Switches: Acceptable

The ceiling lights are functional.

Lights, Wall Switches: Acceptable

The wall switches are functional.

Kitchen-PICTURE
Valves and Connectors: Acceptable

The kitchen valves and connectors below the sink appear functional. Valves were not turned, however no leaking was noted at the time of inspection. Valves are not in daily use and will inevitably become stiff or frozen.

Flooring: Acceptable

The floor is in satisfactory condition and has no significant visible defects.

Inspection of the stand alone refrigerators, freezers and built-in ice makers are outside the scope of the inspection. No opinion is offered as to the adequacy of dishwasher operation. Ovens, self or continuous cleaning operations, cooking functions, clocks, timing devices, lights and thermostat accuracy are not tested during this inspection. Appliances are not moved during the inspection to inspect below or behind them. Portable dishwashers are not inspected, as they require connection to facilitate testing and are sometimes not left with the home.

11 - Kitchen Appliances

Range: Acceptable

The range is functional.

Range: Range type
Gas range
Refrigerator: Acceptable

The fridge was functional and achieved acceptable fridge and freezer temperatures. This is a limited courtesy fridge inspection you should ask the sellers about its full operation. You should make sure to set your fridge at appropriate temps.

Garbage Disposal: Acceptable

Garbage disposal was functional at the time of the inspection. Any deficiencies will be noted below.

$
Credit
Comment
11.2.1 - Garbage Disposal

Cracked Disposal

Garbage disposal was cracked at the time of the inspection. Recommend evaluation and or repair by a qualified licensed professional.

Please visit our Trusted Resources page for a list of contractors who can assist with this.

Handyman

12 - Bathrooms

Sink and Faucet: Acceptable

The sinks were functional.

Trap and Drain: Acceptable

The trap and drain are functional.

Toilet: Acceptable

The toilets were functional, flushes properly and no leaking noted.

Countertop: Acceptable

The countertops were functional.

Cabinets: Acceptable

The cabinets are functional, and do not have any significant damage.

Doors: Acceptable

The door(s) are functional.

Walls and Ceiling: Acceptable

The walls and ceiling are textured drywall and in acceptable condition.

Closet: Acceptable

The closet was inspected and appeared to be in acceptable condition

Closet: Acceptable

The door(s) are functional.

Lights, Wall Switches: Acceptable

The ceiling/wall lights are functional.

Lights, Wall Switches: Acceptable

The wall switches are functional.

Outlets, Electrical Observations: Serviceable

All tested Outlets were serviceable. Any exceptions will be noted.

HVAC: Acceptable

Heating was acceptable.

Bathroom Photos

These photos are to show the condition of the bathrooms at the time of the inspection.

Bathrooms In Acceptable Condition

The bathrooms are overall in acceptable and serviceable condition. Any exceptions will be noted in their perspective areas.

Valves and Connectors: Acceptable

The valves and connectors below the sink appear functional. Valves were not turned, however no leaking was noted at the time of inspection. Valves are not in daily use and will inevitably become stiff or frozen.

Tub-Shower: Acceptable

The tub/shower is functional. Hot and cold water supply temperature was verified and no leaking noted.

Exhaust Fan: Acceptable

The bathroom exhaust fan is functional and works on demand. Any accepting will be noted. 

Our inspection of the bathrooms included a visual examination of the readily accessible portions of the floors, walls, ceilings, cabinets, countertops and plumbing fixtures. Bathrooms are inspected for water drainage, damage, deterioration to floor and walls, proper function of components, active leakage, unusual wear and general state of repair. Bathroom fixtures are run simultaneously to check for adequate water flow and pressure. Fixtures are tested using normal operating controls. Vent fans and their duct work are tested for their proper operation and examined where visible.

Shower pans are visually checked for leakage, but leaks often do not show except when the shower is in actual use. Determining whether shower pans, tub/shower surrounds are water tight is beyond the scope of this inspection. It is very important to maintain all grouting and caulking in the bath areas. Very minor imperfections can allow water to get into the wall or floor areas and cause damage. Proper ongoing maintenance will be required in the future.

$
Credit
Comment
12.4.1 - Tub-Shower

Tub Drain leaks

The tub drain leaks. Recommend repair.

Please visit our Trusted Resources page for a list of contractors who can assist with this.

Plumbing Contractor
$
Credit
Comment
12.5.1 - Toilet

Functional but loose
1st Floor Hallway Bathroom / Master Bathroom

The toilet is functional, but loose on the floor and should be secured by a qualified technician, for safety reasons and to prevent possible damage or leaking from around the toilet.

Please visit our Trusted Resources page for a list of contractors who can assist with this.

Plumbing Contractor
$
Credit
Comment
12.8.1 - Exhaust Fan

No exhaust fan or openable window
Basement Bathroom

There is not a bathroom exhaust fan or openable window installed within this laundry room.  Adding one is recommended and typically required to help disperse excessive moisture from the bathroom.
General Contractor
$
Credit
Comment
12.8.2 - Exhaust Fan

The exhaust fan is noisy
Master Bathroom

The bathroom exhaust fan is functional, but noisy and you may want to upgrade it to a quieter one.
Handyman
$
Credit
Comment
12.10.1 - Walls and Ceiling

Walls have damage
Basement Bathroom

The walls have some damage and repair is recommended 
Drywall Contractor

13 - Laundry

Washer & Dryer: Dryer power source
220 Electric
Exhaust Fan: Acceptable

The laundry exhaust fan was functional.


Doors: Acceptable

The door is functional.

Walls & Ceiling: Acceptable

The walls and ceiling are in acceptable condition.

Cabinets and Shelves: Acceptable

The shelves are satisfactory

Cabinets and Shelves: Acceptable

The cabinets are functional.

Lights, Wall Switches: Acceptable

The ceiling lights are functional.

Lights, Wall Switches: Acceptable

The wall switches are functional.

Outlets, Electrical Observations: Serviceable
Washer & Dryer: Equipment photos
Washer & Dryer: Washer/Dryer Not Tested

A VISUAL ONLY inspection of the washer/dry was performed. Testing washers and dryers is beyond the scope of a home inspection. We were not able to confirm their functionality which includes the testing of plumbing supply lines or valves, discharge lines, pumps, dryer vents and receptacles. We recommend asking the seller about all appliances and whether there are issues that should be disclosed.

Dryer Vent: Acceptable

The visible dryer vent connection appears correct. NOTE: Faulty dryer vents have been responsible for thousands of fires, hundreds of injuries, and even deaths. The best vents are a smooth-walled metal type that travels a short distance; all other types should be regarded as suspect, and should be inspected bi-annually to ensure that they do not contain trapped lint or moisture.

220 Volt Receptacle: 220 In-Use

The 220 volt receptacle for the dryer is in use. Power supply was not tested at the outlet. I recommend you should evaluate this outlet style to be sure the dryer you plan on using here is compatible with it.

Trap & Drain: Acceptable

The washing machine drain line appears satisfactory but is not visible because it's behind or within the wall.

Valves & Connectors: Acceptable

The washing machine valves and connectors appear functional but were not tested. No leaking was noted. However, because they are not in daily use they typically become stiff or frozen.

$
Credit
Comment
13.6.1 - Exhaust Fan

No exhaust fan or openable window

There is not a laundry exhaust fan or openable window installed within this laundry room.  Adding one is recommended and typically required to help disperse excessive moisture from the laundry room.

14 - Interiors, Windows & Doors

Doors: Acceptable

The door(s) are functional.

Walls and Ceiling: Acceptable

The walls and ceiling are textured drywall and in acceptable condition.

Windows: Acceptable

The windows are functional.

Closet: Acceptable

The door(s) are functional.

Closet: Acceptable

The closet was inspected and appeared to be in acceptable condition

Ceiling Fan: Acceptable

The ceiling fan(s) worked on demand.

Lights, Wall Switches: Acceptable

The wall switches are functional.

Lights, Wall Switches: Acceptable

The ceiling lights are functional.

Outlets, Electrical: Acceptable

The outlets were functional. Exceptions will he noted. 

Outlets, Electrical: Light switches acceptable

The light switches were functional during the inspection.

General Notes: Interior Photos

These photos are to show the condition of the interiors at the day of the inspection.

General Notes: Bedrooms Photos

These photos are to show the condition of the bedrooms at the time of the inspection.

General Notes: Interiors in Acceptable condition

Windows, doors, floor and fixtures were overall in acceptable and serviceable condition. This also includes wall, ceilings and and other surfaces. Any exceptions will be noted in their perspective areas.

General Notes: Obsolete two prong ungrounded type
Many outlets throughout the residence are an obsolete, two prong, ungrounded type that are recommended to be evaluated by an electrician, before the close of escrow, and upgraded to have ground-fault protection as a modern safety feature.
Flooring: Acceptable

The floor is in satisfactory condition and has no significant visible defects.

Smoke & CO Detectors Notes: Smoke & carbon Monoxide present

Unless noted otherwise, there was at least the minimally required amount of smoke and CO detectors in the living areas. Our recommendation is that smoke detectors be installed in each bedroom, outside of sleeping areas, and at least one on each floor.  Carbon monoxide detectors should be on each floor. It is recommended they should be checked periodically for fire safety and replaced as necessary.

Fireplace Notes: Type of fireplace & Photo
Wood Burning
Fireplace Notes: Wood Burning Fireplace Acceptable

The Wood burning fireplace appeared to be in functional condition. Note that lighting fires is not part of a home inspection.


The National Fire Protection Association has stated that an in-depth Level 2 chimney inspection should be part of every sale or transfer of property with a wood-burning device. Such an inspection may reveal defects that are not apparent to the home inspector. This is our recommendation as well.

Handrails & Guardrails: Acceptable

The handrail or guardrail on the stairs is satisfactory and in good condition.

Floor Treads & Risers: Acceptable

The stair treads and risers appear satisfactory. The rise should not be less than 4 inches, nor greater than 7 inches, and the treads should not be less than 11 inches. In addition, the dimensions of the treads and the risers should not exceed 3/8 of an inch from the smallest dimension on the entire run of the stairs.

GFCI Notes: GFCI Overview

GFCI (ground fault circuit interrupter) protection is a modern safety device designed to help prevent shock hazards. GFCI breakers and receptacle's function is to de-energize a circuit or a portion of a circuit when a hazardous condition exists. GFCI protection is inexpensive and can provide a substantial increased margin of safety.

Present requirement standards include receptacles near sink and wash basins. In Bathrooms, Kitchen, Garages, Exterior, Crawl Spaces and sump pump equipment.

Miscellaneous Topics Installed: Intercom System

There is an in home intercom system installed in several rooms. Testing of the equipment is beyond the scope of our home inspection. A further inspection and testing could be performed by qualified specialist or with the homeowner. We recommend gathering information of all control locations, features and the proper operation of the system.

Our inspection of the Interior includes a visual inspection of the readily accessible portions of the walls, ceilings, floors, doors, cabinetry, countertops, steps, stairways, balconies and railings. Please note that a representative sample of the accessible windows and electrical receptacles are inspected. These features are examined for proper function, excessive wear and general state of repair. In some cases, all or portions of these components may not be visible because of furnishings and personal items. In these cases some of the items may not be inspected.

The condition of walls behind wall coverings, paneling and furnishings cannot be judged. Only the general condition of visible portions of floors is included in this inspection. As a general rule, cosmetic deficiencies are considered normal wear and tear and are not reported. Determining the source of odors or like conditions is not a part of this inspection. Floor covering damage or stains may be hidden by furniture. The condition of floors underlying floor coverings is not inspected. Determining the condition of insulated glass windows is not always possible due to temperature, weather and lighting conditions. Check with owners for further information.  All fireplaces should be cleaned and inspected on a regular basis to make sure that no cracks have developed. Large fires in the firebox can overheat the firebox and flue liners, sometimes resulting in internal damage.

$
Credit
Comment
14.3.1 - Flooring

Floor Squeaks

The floor in several areas squeaked when walked upon. This is due to driven nails/screws missing the joists. There are several method for repairs. We recommend that repairs be made to eliminate the noise.

Qualified Professional
$
Credit
Comment
14.3.2 - Flooring

Small gaps in flooring

Small gaps were observed on hardwood/laminate flooring. Recommend repairs as needed

Qualified Professional
$
Credit
Comment
14.4.1 - Walls and Ceiling

Normal wear and tear

The walls or ceiling have minor cosmetic damage (scuffs, scrapes, nail holes etc) that you should view yourself and correct as desired.

DIY
$
Credit
Comment
14.4.2 - Walls and Ceiling

moisture stain
Basement

Moisture stains were observed. Recommend monitoring. 

Roofing Professional
$
Credit
Comment
14.5.1 - Windows

Broken seals
Living Room

A window(s) has broken hermetic seals, and should be replaced. This is evident from fogging, or condensation forming between the panes of glass, that confirm that the seal has failed. If you are concerned we recommend that you have a professional check out all the windows within the residence.

Window Repair and Installation Contractor
$
Credit
Comment
14.5.2 - Windows

Screens Damaged/Missing

Window screens were missing or damaged in one or more areas. We recommend repair or replacement as needed.

Qualified Professional
$
Credit
Comment
14.5.3 - Windows

Evidence of previous moisture around windows

Previous moisture stains were observed around windows. Recommend monitoring

Qualified Professional
$
Credit
Comment
14.6.1 - Closet

Door Missing
Master Bedroom

The door is Missing. Recommend replacement as needed.

Qualified Professional
$
Credit
Comment
14.9.1 - Fireplace Notes

Hearth not 16" standard dimensions

The hearth does not have standard dimensions, which would require it to extend at least sixteen inches from the front of the opening, and eight inches on either side. Also, when the fireplace opening is more than six square feet, the hearth should extend at least twenty inches from the front and at least twelve inches on either side.
Fireplace Contractor
$
Credit
Comment
14.9.2 - Fireplace Notes

Chipped tiles on hearth

Basement hearth had chipped tiles recommend repair as needed

Qualified Professional
$
Credit
Comment
14.12.1 - Lights, Wall Switches

Light not working

A light fixture did not have light bulbs or the bulbs were burnt out. Also did not have a globe. Recommend replacing bulbs and testing.

Handyman
$
Credit
Comment
14.13.1 - Outlets, Electrical

Open Grounded Outlet
Multiple locations

A outlet has an open ground, and should be serviced.
Electrical Contractor
$
Credit
Comment
14.13.2 - Outlets, Electrical

Loose outlet

A outlet was loose and should be serviced

Qualified Professional
$
Credit
Comment
14.13.3 - Outlets, Electrical

Missing covers

There were missing covers that should be installed

Handyman

15 - Attic

Attic Access Location
Garage
Insulation Notes: Acceptable

Insulation is acceptable

Insulation Notes: Insulation Type
Balsam wool
Exhaust Ducts: Acceptable

The visible portions of the exhaust ducts appear to be functional.

Plumbing Vents: Acceptable

The accessible plumbing vents were in acceptable condition.

Attic Photos
Method of Evaluation: Entered

The attic was evaluated by direct access to easily accessible areas, and viewed from easy vantage points. Vaulted ceilings have limited access.

Roof Decking Notes: Wood board or plank-Acceptable
The visible portions of the wood board or plank roof decking are in acceptable condition and should conform to the standards of the year in which they were installed.
Ventilation: Ventilation - Acceptable

Ventilation is provided by a combination soffit, gable or roof vents and should be adequate. However, contacting a qualified insulation contractor about having your attic ventilation upgraded could help lower energy costs by cooling down your attic during the warmer summer months.

Our inspection of the Attic includes a visual examination of the roof framing, plumbing, electrical and mechanical systems. There are often heating ducts, bathroom vent ducts, electrical wiring, chimneys and appliance vents in the Attic. We examined these systems and components for proper function, unusual wear and general state of repair, leakage, venting and unusual or improper improvements. When low clearances and deep insulation prohibits walking in an unfinished Attic, inspection will be from the access opening only. Vaulted ceilings cannot be inspected.

$
Credit
Comment
15.3.1 - Roof Decking Notes

Deck Staining

Discoloration and dark staining was observed on the roof sheathing. This is often caused by poor ventilation and is commonly considered a microbial growth. Recommend improving ventilation and cleaning.

$
Credit
Comment
15.5.1 - Insulation Notes

The attic insulation is minimal

The attic insulation is minimal conforming to the year it was built but you may want to add more insulation for a increased r value. 

$
Credit
Comment
15.7.1 - Exhaust Ducts

Bathroom exhaust extend to exterior

The bathroom exhaust ducts should be extended to an exterior vent port. Currently they went into the attic

$
Credit
Comment
15.7.2 - Exhaust Ducts

Kitchen exaust vents into attic

Vent should be routed outside

Qualified Professional

16 - General Comments

General Info

This report is the exclusive property of Idaho Elite Inspection Team and the client whose name appears herewith, and its use by any unauthorized persons is strictly prohibited.

The observations and opinions expressed in this report are those of Idaho Elite Inspection Team and supersede any alleged verbal comments. I inspect all of the systems, components, and conditions described in accordance with the INTERNachi Standards of Practice and those that I do not inspect are clearly disclaimed in the contract and/or in the aforementioned standards. However, some components that are inspected and found to be functional may not necessarily appear in the report, simply because we do not wish to waste our client's time by having them read an unnecessarily lengthy report about components that do not need to be serviced.

In accordance with the terms of the contract, the service recommendations that I make in this report should be completed well before the close of escrow by licensed specialists, who may well identify additional defects or recommend some upgrades that could affect your evaluation of the property.

This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein. All printed comments and the opinions expressed herein are those of the Inspection Company.

Scope of work

You have contracted with Idaho Elite Inspection Team, LLC to perform a generalist inspection in accordance with the standards of practice established by the International Association of Certified Home Inspectors (InterNACHI), a copy of which is available upon request. Generalist inspections are essentially visual, and distinct from those of specialists, inasmuch as they do not include the use of specialized instruments, the dismantling of equipment, or the sampling of air and inert materials. Consequently, a generalist inspection and the subsequent report will not be as comprehensive, nor as technically exhaustive, as that generated by specialists, and it is not intended to be. The purpose of a generalist inspection is to identify significant defects or adverse conditions that would warrant a specialist evaluation. Therefore, you should be aware of the limitations of this type of inspection, which is clearly indicated in the standards. However, the inspection is not intended to document the type of cosmetic deficiencies that would be apparent to the average person, and certainly not intended to identify insignificant deficiencies. Similarly, we do not inspect for vermin infestation, which is the responsibility of a licensed exterminator.


Most homes built after 1978, are generally assumed to be free of asbestos and many other common environmental contaminants. However, as a courtesy to our clients, we are including some well documented, and therefore public, information about several environmental contaminants that could be of concern to you and your family, all of which we do not have the expertise or the authority to evaluate, such as asbestos, radon, methane, formaldehyde, termites and other wood-destroying organisms, pests and rodents, molds, microbes, bacterial organisms, and electromagnetic radiation, to name some of the more commonplace ones. Nevertheless, we will attempt to alert you to any suspicious substances that would warrant evaluation by a specialist. However, health and safety, and environmental hygiene are deeply personal responsibilities, and you should make sure that you are familiar with any contaminant that could affect your home environment. You can learn more about contaminants that can affect your home from a booklet published by The Environmental Protection Agency, which you can read online at www.epa.gov/iaq/pubs/insidest.htm.


MOLD is one such contaminant. It is a microorganism that has tiny seeds, or spores, that are spread in the air then land and feed on organic matter. It has been in existence throughout human history and actually contributes to the life process. It takes many different forms, many of them benign, like mildew. Some characterized as allergens are relatively benign but can provoke allergic reactions among sensitive people, and others characterized as pathogens can have adverse health effects on large segments of the population, such as the very young, the elderly, and people with suppressed immune systems. However, there are less common molds that are called toxins that represent a serious health threat. All molds flourish in the presence of moisture, and we make a concerted effort to look for any evidence of it wherever there could be a water source, including that from condensation. Interestingly, the molds that commonly appear on ceramic tiles in bathrooms do not usually constitute a health threat, but they should be removed. However, some visibly similar molds that form on cellulose materials, such as on drywall, plaster, and wood, are potentially toxigenic. If mold is to be found anywhere within a home, it will likely be in the area of tubs, showers, toilets, sinks, water heaters, evaporator coils, inside attics with unvented bathroom exhaust fans, and return-air compartments that draw outside air, all of which are areas that we inspect very conscientiously. Nevertheless, mold can appear as though spontaneously at any time, so you should be prepared to monitor your home, and particularly those areas that we identified. Naturally, it is equally important to maintain clean air-supply ducts and to change filters as soon as they become soiled because contaminated ducts are a common breeding ground for dust mites, rust, and other contaminants. Regardless, although some mold-like substances may be visually identified, the specific identification of molds can only be determined by specialists and laboratory analysis and is absolutely beyond the scope of our inspection. Nonetheless, as a prudent investment in environmental hygiene, we categorically recommend that you have your home tested for the presence of any such contaminants, and particularly if you or any member of your family suffers from allergies or asthma. Also, you can learn more about mold from an Environmental Protection Agency document entitled "A Brief Guide to Mold, Moisture, and Your Home," by visiting their website at: http://www.epa.gov/iaq/molds/moldguide.html/, from which it can be downloaded.


ASBESTOS is a notorious contaminant that could be present in any home built before 1978. It is a naturally occurring mineral fiber that was first used by the Greek and Romans in the first century, and it has been widely used throughout the modern world in a variety of thermal insulators, including those in the form of paper wraps, bats, blocks, and blankets. However, it can also be found in a wide variety of other products too numerous to mention, including duct insulation and acoustical materials, plasters, siding, floor tiles, heat vents, and roofing products. Although perhaps recognized as being present in some documented forms, asbestos can only be specifically identified by laboratory analysis. The most common asbestos fiber that exists in residential products is chrysotile, which belongs to the serpentine or white-asbestos group, and was used in the clutches and brake shoes of automobiles for many years. However, a single asbestos fiber is said to be able to cause cancer and is, therefore, a potential health threat and a litigious issue. Significantly, asbestos fibers are only dangerous when they are released into the air and inhaled, and for this reason authorities such as the Environmental Protection Agency [EPA] and the Consumer Product Safety Commission [CPSC] distinguish between asbestos that is in good condition, or non-friable, and that which is in poor condition, or friable, which means that its fibers could be easily crumbled and become airborne. However, we are not specialists and, regardless of the condition of any real or suspected asbestos-containing material [ACM], we would not endorse it and recommend having it evaluated by a specialist.


POPCORN CEILING- In early formulations, it often contained white asbestos fibers. When asbestos was banned in ceiling treatments by the Clean Air Act of 1978 in the United States,[1] popcorn ceilings fell out of favor in much of the country. However, in order to minimize economic hardship to suppliers and installers, existing inventories of asbestos-bearing texturing materials were exempt from the ban, so it is possible to find asbestos in popcorn ceilings that were applied through the 1980s. According to the EPA, the use of asbestos in textured ceiling paint was banned in 1977. Inhaled in large quantities, asbestos fibers can cause lung disease, scarring of the lungs and lung cancer. However, not all popcorn ceilings contain asbestos. Moreover, if left undisturbed or contained, asbestos is not dangerous.


RADON is a gas that results from the natural decay of radioactive materials in the soil and is purported to be the second leading cause of lung cancer in the United States. The gas is able to enter homes through the voids around pipes in concrete floors or through the floorboards of poorly ventilated crawlspaces, and particularly when the ground is wet and the gas cannot easily escape through the soil and be dispersed into the atmosphere. However, it cannot be detected by the senses, and its existence can only be determined by sophisticated instruments and laboratory analysis, which is completely beyond the scope of our service. However, you can learn more about radon and other environmental contaminants and their effects on health, by contacting the Environmental Protection Agency (EPA), at www. epa.gov/radon/images/hmbuygud.pdf, and it would be prudent for you to inquire about any high radon readings that might be prevalent in the general area surrounding your home.


LEAD poses an equally serious health threat. In the 1920's, it was commonly found in many plumbing systems. In fact, the word "plumbing" is derived from the Latin word "plumbum," which means lead. When in use as a component of a waste system, it is not an immediate health threat, but as a component of potable water pipes, it is a definite health hazard. Although rarely found in modern use, the lead could be present in any home build as recently as the nineteen forties. For instance, lead was an active ingredient in many household paints, which can be released in the process of sanding, and even be ingested by small children and animals chewing on painted surfaces. Fortunately, the lead in painted surfaces can be detected by industrial hygienists using sophisticated instruments, but testing for it is not cheap. There are other environmental contaminants, some of which we have already mentioned, and others that may be relatively benign. However, we are not environmental hygienists, and as we stated earlier we disclaim any responsibility for testing or establishing the presence of any environmental contaminant, and recommend that you schedule whatever specialist inspections that may deem prudent within the contingency period.


CRACKS AND WINDOWS Unsealed cracks around windows, doors, and thresholds can permit moisture intrusion, which is the principal cause of the deterioration of any surface. Unfortunately, the evidence of such intrusion may only be obvious when it is raining. We have discovered leaking windows while it was raining that may not have been apparent otherwise. Regardless, there are many styles of windows but only two basic types, single and dual-glazed. Dual-glazed windows are superior because they provide a thermal as well as an acoustical barrier. However, the hermetic seals on these windows can fail at any time, and cause condensation to form between the panes. Many environmental factors come into play when and if hermetic seals have failed and Unfortunately, it is not always apparent, which is why we disclaim an evaluation of hermetic seals or unnoticed fogging glass. Nevertheless, in accordance with industry standards, we test a representative number of unobstructed windows and ensure that at least one window in every bedroom is operable and facilitates an emergency exit.


FURTHERMORE, you are advised to seek two professional opinions and acquire estimates of repair as to any defects, comments, improvements or recommendations mentioned in this report. We recommend that the professional making any repairs inspect the property further in order to discover and repair related problems that were not identified in the report. We recommend that all repairs, corrections, and cost estimates be completed and documented prior to closing or purchasing the property. Feel free to hire other professionals to inspect the property prior to closing. Including HVAC professionals, electricians, engineers, window professionals roofers etc.


All conditions are reported as they existed at the time of the inspection. The information contained in this report may be unreliable beyond the date of the inspection due to changing conditions.

17 - Reasonable Expectations of a Home Inspection

Setting Reasonable Expectations

Setting Reasonable Expectations When Things Go Wrong.

There may come a time that you discover something wrong with the house, and you may be upset or disappointed with your home inspection.


Intermittent Or Concealed Problems

Some problems can only be discovered by living in a house. They cannot be discovered during the few hours of a home inspection. For example, some shower stalls leak when people are in the shower, but do not leak when you simply turn on the tap. Some roofs and basements only leak when specific conditions exist. Some problems will only be discovered when carpets were lifted, furniture is moved or finishes are removed.


No Clues

These problems may have existed at the time of the inspection but there were no clues as to their existence. Our inspections are based on the past performance of the house. If there are no clues of a past problem, it is unfair to assume we should foresee a future problem.


We Always Miss Some Minor Things

Some say we are inconsistent because our reports identify some minor problems but not others. The minor problems that are identified were discovered while looking for more significant problems. We note them simply as a courtesy. The intent of the inspection is not to find the $200 problems; it is to find the $2,000 problems. These are the things that affect peoples decisions to purchase.


Contractors Advice

The main source of dissatisfaction with home inspectors comes from comments made by contractors. Contractors opinions often differ from ours. Dont be surprised when three roofers all say the roof needs replacement when we said that, with some minor repairs, the roof will last a few more years.


Last Man In Theory

While our advice represents the most prudent thing to do, many contractors are reluctant to undertake these repairs. This is because of the Last Man In Theory. The contractor fears that if he is the last person to work on the roof, he will get blamed if the roof leaks, regardless of whether the roof leak is his fault or not. Consequently, he wont want to do a minor repair with high liability when he could re-roof the entire house for more money and reduce the likelihood of a callback. This is understandable.


Most Recent Advice Is Best

There is more to the Last Man In Theory. It suggests that it is human nature for homeowners to believe the last bit of expert advice they receive, even if it is contrary to previous advice. As home inspectors, we unfortunately find ourselves in the position of First Man In and consequently it is our advice that is often disbelieved.


Why Didnt We See It

Contractors may say I cant believe you had this house inspected, and they didnt find this problem. There are several reasons for these apparent oversights:


1. Conditions During Inspection

It is difficult for homeowners to remember the circumstances in the house, at the time of the inspection. Homeowners seldom remember that it was snowing, there was storage everywhere in the basement or that the furnace could not be turned on because the air conditioning was operating, et cetera. Its impossible for contractors to know what the circumstances were when the inspection was performed.


2. The Wisdom Of Hindsight

When the problem manifests itself, it is very easy to have 20/20 hindsight. Anybody can say that the basement is wet when there is 2 inches of water on the floor. Predicting the problem is a different story.


3. A Long Look

If we spent 1/2 an hour under the kitchen sink or 45 minutes disassembling the furnace, wed find more problems too. Unfortunately, the inspection would take several days and would cost considerably more.


4. Were Generalists

We are generalists; we are not specialists. The heating contractor may indeed have more heating expertise than we do.


5. An Invasive Look

Problems often become apparent when carpets or plaster are removed, when fixtures or cabinets are pulled out, and so on. A home inspection is a visual examination. We dont perform any invasive or destructive tests.


Not Insurance

In conclusion, a home inspection is designed to better your odds. It is not designed to eliminate all risk. For that reason, a home inspection should not be considered an insurance policy. The premium that an insurance company would have to charge for a policy with no deductible, no limit and an indefinite policy period would be considerably more than the fee we charge. It would also not include the value added by the inspection.

We hope this is food for thought.

18 - Report Conclusion

Conclusion

Congratulations on the purchase of your new home. Since we never know who will be occupying or visiting a property, whether it be children or the elderly, we ask you to consider following these general safety recommendations: install and monitor smoke and carbon monoxide detectors; identify all escape and rescue ports; rehearse an emergency evacuation of the home; upgrade older electrical systems (if present) by at least adding ground-fault outlets; never service any electrical equipment without first disconnecting its power source; safety-film all non-tempered glass; ensure that every elevated window and the railings of stairs, landings, balconies, and decks are child-safe, meaning that barriers are in place or that the distance between the rails is not wider than three inches; regulate the temperature of water heaters to prevent scalding; make sure that goods that contain caustic or poisonous compounds, such as bleach, drain cleaners, and nail polish removers be stored where small children cannot reach them; ensure that all garage doors are well balanced and have a safety device, particularly if they are the heavy wooden type; remove any double-cylinder deadbolts from exterior doors; and consider installing child-safe locks and alarms on the exterior doors of all pool and spa properties.


We are proud of our service and trust that you will be completely satisfied with the quality of our report. We have made every effort to provide you with an accurate assessment of the condition of the property and its components and to alert you to any significant defects or adverse conditions. However, we may not have tested every outlet, and opened every window and door, or identified every minor defect. Also because we are not specialists or because our inspection is essentially visual, latent defects could exist. Therefore, you should not regard our inspection as conferring a guarantee or warranty. It does not. It is simply a report on the general condition of a particular property at a given point in time. Furthermore, as a homeowner, you should expect problems to occur. Roofs will leak, drain lines will become blocked, and components and systems will fail without warning. For these reasons, you should take into consideration the age of the house and its components and keep a comprehensive insurance policy current. If you have been provided with a home protection policy, read it carefully. Such policies usually only cover insignificant costs, such as that of rooter service, and the representatives of some insurance companies can be expected to deny coverage on the grounds that a given condition was preexisting or not covered because of what they claim to be a code violation or manufacturers defect. Therefore, you should read such policies very carefully, and depend upon our company for any consultation that you may need.


FURTHERMORE, you are advised to seek two professional opinions and acquire estimates of repair as to any defects, comments, improvements or recommendations mentioned in this report. We recommend that the professional making any repairs inspect the property further in order to discover and repair related problems that were not identified in the report. We recommend that all repairs, corrections, and cost estimates be completed and documented prior to closing or purchasing the property. Feel free to hire other professionals to inspect the property prior to closing. Including HVAC professionals, electricians, engineers, window professionals roofers etc.


Thank you for taking the time to read this report, and call us if you have any questions or observations whatsoever. I am always attempting to improve the quality of my service and this report, and I will continue to adhere to the highest standards of the real estate industry and to treat everyone with kindness, courtesy, and respect.