Viewing:

1545 4th St
Red Bluff, CA 96080
06/02/2022 1:30 pm

6
Minor concern
22
Moderate concern
10
Major concern

How to read this report:

The defects within the report are organized into three categories. They are Minor Concern (in blue), Moderate Concern (in orange), and Major Concern (in red). The category that each defect is in does not determine the importance of the recommended repair. All defects noted on this report should be addressed. Health and safety concerns will be in the Moderate Concern or Major Concern, depending on how the perceived danger but these should be addressed ASAP. All repairs should be performed by licensed and/or qualified contractors in order to ensure the repairs are done safely and properly.

Minor Concern: Items or components of the home that are defective and, in the opinion of the inspector, may be considered general maintenance or are typical for the age of the home. Any recommended improvements to the home may also be in this category.

Moderate Concern: Items or components that were found to be defective and, if not addressed, these could lead to further problems. These defects are not considered to be routine maintenance. This category may also contain safety hazards or concerns.
Major Concern: Items or components that were defective and may require major/costly repairs.  This category may also contain serious safety hazards or concerns that are in need of immediate attention.

These categories are based on the inspectors professional judgement and are based on the conditions at the time of the inspection. This categorization should not be construed as to mean that items designated as a Minor Concern or Moderate Concern do not need need repaired or addressed. The recommendation in each comment is more important than the category in which the defect was placed in.


Limitations: In the event that the inspector was not able to inspect/test certain areas or components of the home, there may be a Limitations tab in that section of the report. The Limitations tab may show things that need to be further evaluated after the inspection. I recommend reading any Limitations in the report and addressing them as necessary. 


Photographs: Several photos and videos are in your inspection report. These photos are for informational purposes and may not include every instance or occurrence of a defect. For example, if the report has three photos of hail damage on the roof, this does not mean that there is only hail damage in those areas.


1 - Inspection Details

Type of Inspection
Pre-Purchase
Style of Home
Contemporary
In Attendance
None
Occupancy
Vacant, Unfurnished
Utilities
Water, Gas, Electric
Weather
Clear

2 - For Your Information

Orientation: Pictures of the Exterior

The following pictures are of the exterior walls and are intended to help the person reading this report orient themselves with the home or to reference while reading the report. For example, if the Inspector states that there was a defect with a window on the West exterior, this section can be used to view a picture of the West exterior wall. 

Orientation: North Exterior
Orientation: South Exterior
Orientation: East Exterior
Orientation: West Exterior
Electrical - Main Disconnect: Location
On the South Exterior

I recommend that everyone living in the home familiarizes themselves with the location of the electrical service panel and the disconnect used to shut off power to the whole house. Knowing the location of the panel may be beneficial to all members of the family, whether it's to reset a tripped breaker or to disconnect power in the event of an emergency.

Gas - Main Shut Off Valve: Location
Against the South Exterior Wall

I recommend that everyone living in the home familiarizes themselves with the location of the main shut off valve for the gas. If home renovations are being done, it may be necessary to locate and turn off the gas. In the event that natural gas was smelled in the home, I recommend contacting the local utility company and evacuating the home until they evaluate the smell.

Water - Main Shut Off Valve: Location
East Exterior

I recommend that everyone living in the home familiarizes themselves with the location of the main shut off valve for the water. In the event of a plumbing emergency, knowing where it is and how to turn the water off can limit damage and save time, money and avoid costly repairs from water damage.

3 - Roof Coverings & Drainage

General: Descriptions:

The materials, styles and components present and observable are described as follows:

General: Inspection Method
Roof, Ladder, Ground
General: Roof Type / Style
Gable
Coverings: Pictures of the Roof
Coverings: Material
Asphalt Architectural Shingles

I. The inspector shall inspect from ground level or the eaves: A. the roof-covering materials; B. the gutters; C. the downspouts; D. the vents, flashing, skylights, chimney, and other roof penetrations; and E. the general structure of the roof from the readily accessible panels, doors or stairs. II. The inspector shall describe: A. the type of roof-covering materials. III. The inspector shall report as in need of correction: A. observed indications of active roof leaks. IV. The inspector is not required to: A. walk on any roof surface. B. predict the service life expectancy. C. inspect underground downspout diverter drainage pipes. D. remove snow, ice, debris or other conditions that prohibit the observation of the roof surfaces. E. move insulation. F. inspect antennae, satellite dishes, lightning arresters, de-icing equipment, or similar attachments. G. walk on any roof areas that appear, in the inspectors opinion, to be unsafe. H. walk on any roof areas if doing so might, in the inspector's opinion, cause damage. I. perform a water test. J. warrant or certify the roof. K. confirm proper fastening or installation of any roof-covering material.

$
Credit
Comment
3.4.1 - Gutters

Missing in Areas

Gutters are missing in areas. In order to prevent rain water from getting near the foundation, I recommend having gutters added. 

Gutter Contractor

4 - Exterior

Descriptions:

The materials, styles and components present and observable are described as follows:

Inspection Method
Ladder, Roof, Ground
Windows: Windows - Single Pane

The windows were noted to be single pane and likely original to the home. You should be aware that this will lead to decreased energy efficiency. 

I. The inspector shall inspect: A. the exterior wall-covering materials, flashing and trim; B. all exterior doors; C. adjacent walkways and driveways; D. stairs, steps, stoops, stairways and ramps; E. porches, patios, decks, balconies and carports; F. railings, guards and handrails; G. the eaves, soffits and fascia; H. a representative number of windows; and I. vegetation, surface drainage, retaining walls and grading of the property, where they may adversely affect the structure due to moisture intrusion. II. The inspector shall describe: A. the type of exterior wall-covering materials. III. The inspector shall report as in need of correction: A. any improper spacing between intermediate balusters, spindles and rails. IV. The inspector is not required to: A. inspect or operate screens, storm windows, shutters, awnings, fences, outbuildings, or exterior accent lighting. B. inspect items that are not visible or readily accessible from the ground, including window and door flashing. C. inspect or identify geological, geotechnical, hydrological or soil conditions. D. inspect recreational facilities or playground equipment. E. inspect seawalls, breakwalls or docks. F. inspect erosion-control or earth-stabilization measures. G. inspect for safety-type glass. H. inspect underground utilities. I. inspect underground items. J. inspect wells or springs. K. inspect solar, wind or geothermal systems. L. inspect swimming pools or spas. M. inspect wastewater treatment systems, septic systems or cesspools. N. inspect irrigation or sprinkler systems. O. inspect drainfields or dry wells. P. determine the integrity of multiple-pane window glazing or thermal window seals.

$
Credit
Comment
4.2.1 - Stucco

Stucco - Poor Condition

The stucco is in overall poor condition. Due to the amount of defects observed, I recommend having the stucco evaluated and repaired as necessary by a licensed contractor who specializes in stucco.

Stucco Repair Contractor
$
Credit
Comment
4.3.1 - Exterior Doors

Damaged

The exterior door(s) was damaged. I recommend having the door evaluated and repaired/replaced as desired. 

Door Repair and Installation Contractor
$
Credit
Comment
4.3.2 - Exterior Doors

Recommend Deadbolt
East & West Exterior Doors

The exterior door(s) does not have a deadbolt lock installed. In order to increase the security of the home, I recommend having a deadbolt added. 

Door Repair and Installation Contractor
$
Credit
Comment
4.3.3 - Exterior Doors

Repair/Replace Weatherstripping
West Exterior

The weatherstripping on the exterior door(s) is in need of repair. In order to prevent energy loss, I recommend having it replaced. 

Qualified Professional
$
Credit
Comment
4.3.4 - Exterior Doors

Exterior Door - Hollow Core
West Exterior Door

There was an interior hollow core door being used as an exterior door. For security and energy efficiency reasons, I recommend an exterior rated door be installed. 

Qualified Professional
$
Credit
Comment
4.5.1 - Sidewalks, Patios, Porches, & Driveways

Guardrails/Handrails - Loose

Areas of the guardrails/handrails are loose. In order to increase the overall safety of the home and to prevent accidents/injuries, I recommend having this evaluated and repaired as necessary. 

Qualified Professional
$
Credit
Comment
4.5.2 - Sidewalks, Patios, Porches, & Driveways

Car Port/Patio Cover - Moisture Damage / Rot

Rot and/or moisture damage was observed on areas of the patio cover. I recommend having the patio cover evaluated and repaired as necessary by a qualified contractor. 

Qualified Professional
$
Credit
Comment
4.5.3 - Sidewalks, Patios, Porches, & Driveways

Post - Moisture Damage

The bottom of the post has apparent moisture damage/rot. This should be repaired for increased stability to the porch cover. 

Qualified Professional
$
Credit
Comment
4.7.1 - Vegetation, Grading, Drainage & Retaining Walls

Vegetation - Overhanging The Roof

Tree branches were overhanging the roof in areas. Branches overhanging the roof can cause leaves to clog gutters, branches could fall and cause damage, and critters can use branches to get onto the home. I recommend having the overhanging trees trimmed back to avoid any issues. 

Tree Service
$
Credit
Comment
4.7.2 - Vegetation, Grading, Drainage & Retaining Walls

Vegetation - Covering Gas Meter

Vegetation has overgrown the gas meter. In order to prevent the gas vent from becoming blocked, I recommend the vegetation be trimmed back/removed. 

Qualified Professional

5 - Doors, Windows & Interior

Descriptions:

The materials, styles and components present and observable are described as follows:

Windows: Material
Aluminum
Floors: Interior Flooring
Countertops & Cabinets: Countertops/Cabinets

I. The inspector shall inspect: A. a representative number of doors and windows by opening and closing them; B. floors, walls and ceilings; C. stairs, steps, landings, stairways and ramps; D. railings, guards and handrails; and E. garage vehicle doors and the operation of garage vehicle door openers, using normal operating controls. II. The inspector shall describe: A. a garage vehicle door as manually-operated or installed with a garage door opener. III. The inspector shall report as in need of correction: A. improper spacing between intermediate balusters, spindles and rails for steps, stairways, guards and railings; B. photo-electric safety sensors that did not operate properly; and C. any window that was obviously fogged or displayed other evidence of broken seals. IV. The inspector is not required to: A. inspect paint, wallpaper, window treatments or finish treatments. B. inspect floor coverings or carpeting. C. inspect central vacuum systems. D. inspect for safety glazing. E. inspect security systems or components. F. evaluate the fastening of islands, countertops, cabinets, sink tops or fixtures. G. move furniture, stored items, or any coverings, such as carpets or rugs, in order to inspect the concealed floor structure. H. move suspended-ceiling tiles. I. inspect or move any household appliances. J. inspect or operate equipment housed in the garage, except as otherwise noted. K. verify or certify the proper operation of any pressure-activated auto-reverse or related safety feature of a garage door. L. operate or evaluate any security bar release and opening mechanisms, whether interior or exterior, including their compliance with local, state or federal standards. M. operate any system, appliance or component that requires the use of special keys, codes, combinations or devices. N. operate or evaluate self-cleaning oven cycles, tilt guards/latches, or signal lights. O. inspect microwave ovens or test leakage from microwave ovens. P. operate or examine any sauna, steamgenerating equipment, kiln, toaster, ice maker, coffee maker, can opener, bread warmer, blender, instant hot-water dispenser, or other small, ancillary appliances or devices. Q. inspect elevators. R. inspect remote controls. S. inspect appliances. T. inspect items not permanently installed. U. discover firewall compromises. V. inspect pools, spas or fountains. W. determine the adequacy of whirlpool or spa jets, water force, or bubble effects. X. determine the structural integrity or leakage of pools or spas.

$
Credit
Comment
5.2.1 - Windows

Window Sill - Moisture Damage
East Living Room Window

Areas of the interior window sill had apparent moisture damage that appears to have been repaired. No moisture was present at the time of inspection. I recommend asking seller about the repair. 

Qualified Professional
$
Credit
Comment
5.3.1 - Floors

Flooring - Damage

Multiple areas of the flooring have damage/imperfections present. I recommend having the flooring evaluated and addressed as desired. 

Flooring Contractor
$
Credit
Comment
5.3.2 - Floors

Moisture Damage Around Toilet
Bathroom

The toilet area in the bathroom has moisture damage to the flooring. I recommend having this evaluated and repaired/addressed as necessary 

Qualified Professional
$
Credit
Comment
5.4.1 - Walls

Drywall - Multiple Repairs Needed

Throughout the home, multiple areas of the interior walls appeared to be in need of drywall repair. I recommend having the home evaluated by a drywall contractor in order to have the damaged or missing drywall areas properly repaired.

Drywall Contractor
$
Credit
Comment
5.4.2 - Walls

Mold Like Substance
Northwest Bedroom

A mold like substance was observed. I recommend having this tested by a licensed mold inspector, and remediated as necessary. 

Mold Inspector
$
Credit
Comment
5.4.3 - Walls

Backsplash - Damage

The kitchen sink backsplash is damaged and pulling away from the wall. This should be repaired to avoid moisture damage to the wall behind it. 

Qualified Professional
$
Credit
Comment
5.5.1 - Ceilings

Drywall - Repair Needed

Areas of the ceiling drywall are in need of repair. I recommend having the repairs made by a qualified drywall contractor.

Drywall Contractor
$
Credit
Comment
5.6.1 - Countertops & Cabinets

Cabinet - Evidence of a Past Leak

Damage was observed in the bottom of a cabinet, below the sink. This area was not leaking at the time of the inspection, however I recommend monitoring it over time for leaks and having the damage repaired. 

Qualified Professional
$
Credit
Comment
5.6.2 - Countertops & Cabinets

Cabinet - Possible Mold
Bathroom Under Sink

A mold like substance was observed. I recommend having this tested by a licensed mold inspector, and remediated as necessary. 

Mold Inspector

6 - Built-In Appliances

Refrigerator: Refrigerator

The refrigerator was visually inspected and a temperature was taken inside the refrigerator and freezer to ensure that they were cooling properly. Any ice/water dispensers present were tested. Any defects are noted below.

Range/Oven Combination: Range/Oven Combination

The range/oven was visually inspected and each burner/element was checked to ensure they were heating. Any defects are noted below.

Range/Oven Combination: Range/Oven Energy Source
Gas
Range Hood: Range Hood

The range hood was visually inspected and the exhaust fan and light were tested. Any defects are noted below.

Range Hood: Venting Method
None
Refrigerator: Refrigerator - Not Tested Due to Being Unplugged

The refrigerator was unplugged therefore was not tested.

Range/Oven Combination: Unable to Test - No Gas/Propane

The gas/propane was shut off and/or empty, therefore the range was not tested or inspected. 

10.1 The inspector shall inspect: F. installed ovens, ranges, surface cooking appliances, microwave ovens, dishwashing machines, and food waste grinders by using normal operating controls to activate the primary function. 10.2 The inspector is NOT required to inspect: G. installed and free-standing kitchen and laundry appliances not listed in Section 10.1.F. H. appliance thermostats including their calibration, adequacy of heating elements, self cleaning oven cycles, indicator lights, door seals, timers, clocks, timed features, and other specialized features of the appliance. I. operate, or con rm the operation of every control and feature of an inspected appliance.

$
Credit
Comment
6.3.1 - Range Hood

No range hood Installed

There appears to be no range hood exhaust installed over the range/oven. To prevent excessive moisture in the home, I recommend one be installed. 

Qualified Professional

7 - Roof Structure & Attic

Descriptions:

The materials, styles and components present and observable are described as follows:

Roof Structure & Attic: Pictures of Attic
Roof Structure & Attic: Decking Material
Plywood
Limited Access - In Closet

Due to the attic access being in a narrow closet, access was limited In the attic. 

Limited Access - Obstructions

The attic access was limited due to obstructions (wires) blocking the opening. 

$
Credit
Comment
7.1.1 - Roof Structure & Attic

Attic Hatch - Missing Cover

The attic hatch does not have a cover installed. In order to prevent air leakage into the attic, which can lead to condensation and energy loss, I recommend having a proper access cover installed. 

Qualified Professional

8 - Electrical

Descriptions:

The materials, styles and components present and observable are described as follows:

Service Entrance Conductors: Service Method
Overhead
Service Entrance Conductors: Conductor Material
Copper
Service Entrance Conductors: Voltage
220 Volt
Service Panel: Picture of Inside Service Panel
Service Panel: Main Panel Location
On the South Exterior Wall
Service Panel: Panel Amperage
60 AMP
Service Panel: Equipment in Panel
Circuit Breaker
Service Panel: 60 Amp Service

The home appeared to have 60 amp service, which is small by todays standards. Be aware that the use of multiple electrical devices, particularly ones with heating elements, could result in frequently tripped breakers. 

Sub Panel: Sub Panel Location
Bedroom Closet
Sub Panel: Equipment in Panel
Circuit Breakers
Branch Wiring Circuits, Breakers & Fuses: Branch Wiring
Copper
Branch Wiring Circuits, Breakers & Fuses: Type of Sheathing
Non Metallic, Cloth Wiring
Branch Wiring Circuits, Breakers & Fuses: Ungrounded System - Partial

This home had older ungrounded wiring for some or most receptacles. Not all receptacles are shown. Grounding systems are installed to provide a pathway to the earth for high voltage from lighting strikes and electrical surges, accidental contact with higher voltage lines, and to help stabilize the electrical system during normal operation. 

This condition may have complied with the safety standards in effect when the home was built, but as electrical knowledge has improved over the years, standards have changed. Homes are not required to be constantly updated to comply with new standards. 

I recommend that you consult with a qualified electrical contractor to discuss options if desired. 

Fixtures, Fans, Switches & Receptacles: Exterior Light Fixtures Disclaimer

Exterior light fixtures can be on motion detectors, from dusk to dawn sensors, timers, etc. For this reason, we are not always able to confirm whether exterior lights work.

No Electricity

There was no electricity to the home at the time of the inspection, therefore the electrical system could not be fully inspected.  

I. The inspector shall inspect: A. the service drop; B. the overhead service conductors and attachment point; C. the service head, gooseneck and drip loops; D. the service mast, service conduit and raceway; E. the electric meter and base; F. service-entrance conductors; G. the main service disconnect; H. panelboards and over-current protection devices (circuit breakers and fuses); I. service grounding and bonding; J. a representative number of switches, lighting fixtures and receptacles, including receptacles observed and deemed to be arc-fault circuit interrupter (AFCI)-protected using the AFCI test button, where possible; K. all ground-fault circuit interrupter receptacles and circuit breakers observed and deemed to be GFCIs using a GFCI tester, where possible; and L. smoke and carbon-monoxide detectors. II. The inspector shall describe: A. the main service disconnect's amperage rating, if labeled; and B. the type of wiring observed. III. The inspector shall report as in need of correction: A. deficiencies in the integrity of the serviceentrance conductors insulation, drip loop, and vertical clearances from grade and roofs; B. any unused circuit-breaker panel opening that was not filled; C. the presence of solid conductor aluminum branch-circuit wiring, if readily visible; D. any tested receptacle in which power was not present, polarity was incorrect, the cover was not in place, the GFCI devices were not properly installed or did not operate properly, evidence of arcing or excessive heat, and where the receptacle was not grounded or was not secured to the wall; and E. the absence of smoke detectors. IV. The inspector is not required to: A. insert any tool, probe or device into the main panelboard, sub-panels, distribution panelboards, or electrical fixtures. B. operate electrical systems that are shut down. C. remove panelboard cabinet covers or dead fronts. D. operate or re-set over-current protection devices or overload devices. E. operate or test smoke or carbon-monoxide detectors or alarms F. inspect, operate or test any security, fire or alarms systems or components, or other warning or signaling systems. G. measure or determine the amperage or voltage of the main service equipment, if not visibly labeled. H. inspect ancillary wiring or remote-control devices. I. activate any electrical systems or branch circuits that are not energized. J. inspect low-voltage systems, electrical de-icing tapes, swimming pool wiring, or any timecontrolled devices. K. verify the service ground. L. inspect private or emergency electrical supply sources, including, but not limited to: generators, windmills, photovoltaic solar collectors, or battery or electrical storage facility. M. inspect spark or lightning arrestors. N. inspect or test de-icing equipment. O. conduct voltage-drop calculations. P. determine the accuracy of labeling. Q. inspect exterior lighting.

$
Credit
Comment
8.2.1 - Service Panel

Dead Front Cover - Pointed Screws

 The screw(s) that secure the dead front cover to the service panel were pointed screws. This presents a safety hazard due to the pointed screws being able to pierce an electrical conductor. I recommend having the cover properly secured with blunt tipped screws. 

Electrical Contractor
$
Credit
Comment
8.2.2 - Service Panel

Service Ground - Recommend Evaluation
South Exterior

The electrical service appeared to be improperly grounded. The grounding conductor was broken/detached from the grounding rod. In order to prevent electrical shocks, I recommend having the ground evaluated and repaired as necessary by a licensed electrician.

Electrical Contractor
$
Credit
Comment
8.2.3 - Service Panel

Missing Knockout Plugs/Filler Plates

The unused opening(s) inside the service panel were not properly covered. When breaker knockouts or wire knockouts are removed and are no longer being used, knockout plugs or filler plates should be installed. In order to prevent electrocution, I recommend having the openings properly covered/filled. 

Electrical Contractor
$
Credit
Comment
8.3.1 - Sub Panel

Knockout Plugs/Filler Plates - Missing

Unused openings were observed in the service panel. When breaker knockouts or wire knockouts are removed and are not no longer being used, I recommend having the openings covered in order to prevent any shock hazards. I recommend having knockout plugs or filler plates installed. 

Electrical Contractor
$
Credit
Comment
8.4.1 - Branch Wiring Circuits, Breakers & Fuses

Recommend Evaluation

Due to the fact that there was no electricity to the home at the time of inspection, and the multiple issues found. I recommend having the electrical system and circuits evaluated by a licensed electrician.

Electrical Contractor
$
Credit
Comment
8.5.1 - Fixtures, Fans, Switches & Receptacles

Cover Plate - Missing

A cover plate was missing in multiple areas. Not only do cover plates help to prevent accidental shocks, but they help to contain any arcing or sparking that might take place within an electrical box, thus potentially preventing a fire. I recommend having the missing cover plates replaced. 

Handyman
$
Credit
Comment
8.5.2 - Fixtures, Fans, Switches & Receptacles

Receptacle - 2 Prong

Older 2 prong receptacles were observed, which are not grounded. Although this was common in older homes, I recommend having them properly grounded by a licensed electrician in order to increase the safety of the home.

Electrical Contractor
$
Credit
Comment
8.6.1 - GFCI & AFCI

GFCI Protection Not Installed

The receptacle(s) were not GFCI protected. In order to protect against electrical shock, I recommend having all receptacles in the garage, on the exterior, and near any water sources such as bathrooms and kitchens protected by GFCI receptacles. For safety reasons, I recommend having  GFCI protection installed. 

Electrical Contractor
$
Credit
Comment
8.7.1 - Smoke & Carbon Monoxide Alarms

CO Alarm - None

No CO alarms were observed in the home. I recommend having a CO alarm installed on each level of the home and within 15 feet of each sleeping room.

Qualified Professional
$
Credit
Comment
8.7.2 - Smoke & Carbon Monoxide Alarms

Smoke Alarm - None

There were no visible smoke alarms in the home. I recommend having proper smoke alarms within 15 feet of all sleeping rooms, and one on each floor of the home.

Qualified Professional

9 - Plumbing

Descriptions:

The materials, styles and components present and observable are described as follows:

Source of Water Supply
Public
Drain, Waste, & Vent Systems: Material
Iron, PVC
Water Supply: Water Supply Material
Galvanized
Water Supply: Distribution Material
Galvanized
Water Supply: Water Pressure

The water pressure was measured with a pressure gauge at an exterior faucet. I recommend the water pressure be between 40 psi and 80 psi. Any concerns with the pressure are noted below.

Atmospheric Water Heater: Water Heater

The water heater(s) was visually inspected in order to ensure proper installation and that no leaks, rust, or corrosion were present. The temperature of the water was also checked to ensure the water heater was functioning properly. The American Society of Sanitary Engineering recommends setting the temperature of home water heaters to 135 degrees to 140 degrees Fahrenheit, a range shown to destroy bacteria such as Legionella. At those temperatures, bacteria can neither thrive or survive to contaminate fixtures downstream from the heater. Adjusting a water heater to a higher temperature must always be accompanied by the installation of anti-scald devices in the home by a licensed plumber to prevent potential burn injuries.

Any defects are noted below.

Here is a nice maintenance guide from Lowe's to help.

Atmospheric Water Heater: Manufacturer
General Sentinel
Atmospheric Water Heater: Location
Closet in Kitchen
Atmospheric Water Heater: Capacity
30 Gallon
Atmospheric Water Heater: Approximate Age
00 Unknown

The age of the water heater could not be determined using the resources available for determining appliance age. 

Atmospheric Water Heater: Power Source/Type
Gas

I. The inspector shall inspect: A. the main water supply shut-off valve; B. the main fuel supply shut-off valve; C. the water heating equipment, including the energy source, venting connections, temperature/pressure-relief (TPR) valves, Watts 210 valves, and seismic bracing; D. interior water supply, including all fixtures and faucets, by running the water; E. all toilets for proper operation by flushing; F. all sinks, tubs and showers for functional drainage; G. the drain, waste and vent system; and H. drainage sump pumps with accessible floats. II. The inspector shall describe: A. whether the water supply is public or private based upon observed evidence; B. the location of the main water supply shut-off valve; C. the location of the main fuel supply shut-off valve; D. the location of any observed fuel-storage system; and E. the capacity of the water heating equipment, if labeled. III. The inspector shall report as in need of correction: A. deficiencies in the water supply by viewing the functional flow in two fixtures operated simultaneously; B. deficiencies in the installation of hot and cold water faucets; C. mechanical drain stops that were missing or did not operate if installed in sinks, lavatories and tubs; and D. toilets that were damaged, had loose connections to the floor, were leaking, or had tank components that did not operate. IV. The inspector is not required to: A. light or ignite pilot flames. B. measure the capacity, temperature, age, life expectancy or adequacy of the water heater. C. inspect the interior of flues or chimneys, combustion air systems, water softener or filtering systems, well pumps or tanks, safety or shut-off valves, floor drains, lawn sprinkler systems, or fire sprinkler systems. D. determine the exact flow rate, volume, pressure, temperature or adequacy of the water supply. E. determine the water quality, potability or reliability of the water supply or source. F. open sealed plumbing access panels. G. inspect clothes washing machines or their connections. H. operate any valve. I. test shower pans, tub and shower surrounds or enclosures for leakage or functional overflow protection. J. evaluate the compliance with conservation, energy or building standards, or the proper design or sizing of any water, waste or venting components, fixtures or piping. K. determine the effectiveness of anti-siphon, backflow prevention or drain-stop devices. L. determine whether there are sufficient cleanouts for effective cleaning of drains. M. evaluate fuel storage tanks or supply systems. N. inspect wastewater treatment systems. O. inspect water treatment systems or water filters. P. inspect water storage tanks, pressure pumps, or bladder tanks. Q. evaluate wait time to obtain hot water at fixtures, or perform testing of any kind to water heater elements. R. evaluate or determine the adequacy of combustion air. S. test, operate, open or close: safety controls, manual stop valves, temperature/pressure-relief valves, control valves, or check valves. T. examine ancillary or auxiliary systems or components, such as, but not limited to, those related to solar water heating and hot water circulation. U. determine the existence or condition of polybutylene plumbing. V. inspect or test for gas or fuel leaks, or indications thereof.

$
Credit
Comment
9.1.1 - Drain, Waste, & Vent Systems

Tub Drain - Active Leak
Crawlspace

The tub drain was actively leaking. This should be repaired to avoid water damage. 

Plumbing Contractor
$
Credit
Comment
9.4.1 - Atmospheric Water Heater

Water Heater - Past it's Life Expectancy

Although the water heater is functioning, it appears to be past it’s expected service life. You should be aware of this. 

Plumbing Contractor
$
Credit
Comment
9.5.1 - Fixtures

Bathroom Sink - Drain Assembly Leaking
Bathroom

The bathroom sink(s) leaked at drain assembly. I recommend having this evaluated and repaired/replaced as necessary in order to prevent water damage. 

Plumbing Contractor

10 - Heating

Gas Wall Furnace: Picture of Gas Wall Furnace
Gas Wall Furnace: Approximate Age
38 Years Old
Gas Wall Furnace: Descriptions:

The materials, styles and components present and observable are described as follows:

Gas Wall Furnace: Energy Source
Natural Gas
Gas Wall Furnace: Thermostat Location
None Found
Gas Wall Furnace: Unable to Inspect - Gas Turned Off at Service Shut-Off

The gas supply to the furnace was shut off at the shut-off valve near the furnace, therefore it was not tested or thoroughly inspected.

I. The inspector shall inspect: A. the heating system, using normal operating controls. II. The inspector shall describe: A. the location of the thermostat for the heating system; B. the energy source; and C. the heating method. III. The inspector shall report as in need of correction: A. any heating system that did not operate; and B. if the heating system was deemed inaccessible. IV. The inspector is not required to: A. inspect or evaluate the interior of flues or chimneys, fire chambers, heat exchangers, combustion air systems, fresh-air intakes, humidifiers, dehumidifiers, electronic air filters, geothermal systems, or solar heating systems. B. inspect fuel tanks or underground or concealed fuel supply systems. C. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the heating system. D. light or ignite pilot flames. E. activate heating, heat pump systems, or other heating systems when ambient temperatures or other circumstances are not conducive to safe operation or may damage the equipment. F. override electronic thermostats. G. evaluate fuel quality. H. verify thermostat calibration, heat anticipation, or automatic setbacks, timers, programs or clocks.

$
Credit
Comment
10.1.1 - Gas Wall Furnace

Clean, Service, and Certify - Due to Age

The age of the furnace is near or is past the average life expectancy of a furnace. In addition to having the system cleaned, I also recommend having the system certified by a licensed HVAC contractor. A certification is a more thorough inspection, which typically includes inspecting the heat exchanger. On older furnaces, it's common for cracks to form in the heat exchanger, which can allow carbon monoxide to enter the home.

HVAC Professional

11 - Insulation & Ventilation

Descriptions:

The materials, styles and components present and observable are described as follows:

Crawlspace / Basement Wall Insulation: Insulation Type
None
Flooring Insulation: Insulation Type
None
Attic Insulation: Insulation Type
Loose-fill Cellulose
Attic Insulation: Average Depth of Insulation
8"-10"
Ventilation & Exhaust : Ventilation Type
Gable Vents
Ventilation & Exhaust : Bathroom Ventilation
None

I. The inspector shall inspect: A. insulation in unfinished spaces, including attics, crawlspaces and foundation areas; B. ventilation of unfinished spaces, including attics, crawlspaces and foundation areas; and C. mechanical exhaust systems in the kitchen, bathrooms and laundry area. II. The inspector shall describe: A. the type of insulation observed; and B. the approximate average depth of insulation observed at the unfinished attic floor area or roof structure. III. The inspector shall report as in need of correction: A. the general absence of insulation or ventilation in unfinished spaces. IV. The inspector is not required to: A. enter the attic or any unfinished spaces that are not readily accessible, or where entry could cause damage or, in the inspector's opinion, pose a safety hazard. B. move, touch or disturb insulation. C. move, touch or disturb vapor retarders. D. break or otherwise damage the surface finish or weather seal on or around access panels or covers. E. identify the composition or R-value of insulation material. F. activate thermostatically operated fans. G. determine the types of materials used in insulation or wrapping of pipes, ducts, jackets, boilers or wiring. H. determine the adequacy of ventilation.

12 - Foundation & Structure

Descriptions:

The materials, styles and components present and observable are described as follows:

Foundation: Style
Crawlspace
Foundation: Material
Concrete
Foundation: Location of Crawl Space Entrance
Access Door
Floor Structure: Joist/Support Material
Wood Joists
Floor Structure: Post Material
Wood Post
Floor Structure: Sub-floor
Plywood
Floor Structure: Basement/Crawlspace Floor
Dirt

I. The inspector shall inspect: A. the foundation; B. the basement; C. the crawlspace; and D. structural components. II. The inspector shall describe: A. the type of foundation; and B. the location of the access to the under-floor space. III. The inspector shall report as in need of correction: A. observed indications of wood in contact with or near soil; B. observed indications of active water penetration; C. observed indications of possible foundation movement, such as sheetrock cracks, brick cracks, out-of-square door frames, and unlevel floors; and D. any observed cutting, notching and boring of framing members that may, in the inspector's opinion, present a structural or safety concern. IV. The inspector is not required to: A. enter any crawlspace that is not readily accessible, or where entry could cause damage or pose a hazard to him/herself. B. move stored items or debris. C. operate sump pumps with inaccessible floats. D. identify the size, spacing, span or location or determine the adequacy of foundation bolting, bracing, joists, joist spans or support systems. E. provide any engineering or architectural service. F. report on the adequacy of any structural system or component.

$
Credit
Comment
12.1.1 - Foundation

Crawlspace Entrance - Seal

The crawlspace entrance does not have a proper cover. In order to prevent unwanted pests from entering the crawlspace, I recommend a proper cover be installed. 

Qualified Professional
$
Credit
Comment
12.2.1 - Floor Structure

Floor Structure - Moisture Damage
Crawlspace

There was moisture damage noted to the floor structure below the toilet area. The floor around the toilet was soft as well. This should be repaired as necessary by a qualified contractor. 

Qualified Professional

13 - Checklist

General: Final Checklist

It is our goal to treat every home with respect and leave them in the same condition as when we arrived. The following are steps that were taken as part of our final checklist in order to ensure that everything was reset to it's original position/condition.

General: Main Water Shut-Off Turned Back Off

The main water shutoff was turned on in order to inspect the plumbing system. It was shut back off at the end of the inspection.