The purpose of the Rental Property Condition Inspection is to report on readily observable conditions. This is not a detailed or exhaustive inspection of the homes components, functions or features.
Mike Barnhill
The purpose of the Rental Property Condition Inspection is to report on readily observable conditions and safety concerns. This is not a detailed or exhaustive inspection of the homes components, functions or features.
Where recommendations are made they are conveyed for the purpose of preventing damage or preventing injury to occupants.
The purpose of the Rental Property Condition Inspection is to report on readily observable conditions. This is not a detailed or exhaustive inspection of the homes components, functions or features.
Lock box and contents were present
G | F | P | NI | NA | ||
---|---|---|---|---|---|---|
2.1 | Landscaping and Yard | X | ||||
2.2 | Fences and Gates | X | ||||
2.3 | Siding, Trim, Lights, Electrical | X | ||||
2.4 | Windows and Doors | X | ||||
2.5 | Walks, Driveway, Porches and Patios | X | ||||
2.6 | Garage | X | ||||
2.7 | Roof and Gutters | X |
The roof was viewed from the ground. Observations are limited to those portions of the roof that can be seen from the ground.
Keep all downspout extensions or splash blocks in place
G | F | P | NI | NA | ||
---|---|---|---|---|---|---|
3.1 | Basement/Crawlspace | X | ||||
3.2 | Plumbing and Drains | X | ||||
3.3 | Furnace Filter | X | ||||
3.4 | Electrical | X | ||||
3.5 | Kitchen Cabinets/Counters/Fixtures | X | ||||
3.6 | Kitchen Walls and Floors | X | ||||
3.7 | Kitchen Appliances | X | ||||
3.8 | Bathroom Cabinets/Counters/Fixtures | X | ||||
3.9 | Bathroom Walls and Floors | X | ||||
3.10 | Interior Doors | X | ||||
3.11 | Walls and Floors | X | ||||
3.12 | Stairs | X |
A Water Alarm is Not present
One or More toilets is/are not bolted down and may be leaking at the base.
G | F | P | NI | NA | ||
---|---|---|---|---|---|---|
4.1 | Garage Door Safety Reverse | X | ||||
4.2 | Furnace and Water Heater Drafting | X | ||||
4.3 | Gas Leak Check | X | ||||
4.4 | GFCI's (Ground Fault Circuit Interrupt) | X | ||||
4.5 | Stove Anti Tip | X | ||||
4.6 | Smoke and Carbon Monoxide Detectors | X | ||||
4.7 | Fire Extinguisher | X |
Required in each Sleeping Room, Adjoining Area and on each Level of the home.
Required within 15 feet of each sleeping room.
Recommended on each level of the home.
The optical sensors are above the 4-6 inch requirement of the manufacturer. Reinstall them in accordance with the manufacturers instructions
GFCI (Ground Fault Circuit Interrupt ) Outlets should be installed in Kitchens, Bathrooms, Garages and Outdoors outlets. There were not GFCI's in the following location(s):
Garage
The smoke detector in the basement was not working when tested.