2011 Victory Avenue                                            Tel: 940-696-0520
Wichita Falls, Texas  76301       

Inspection Agreement

Accurate Inspections, herein after known as the Inspector agrees to conduct an inspection for the purpose of informing the client of major deficiencies in the condition of the property listed above.  THE WRITTEN REPORT IS THE PROPERTY OF THE CLIENT AND Accurate Inspections, AND SHALL NOT BE USED BY OR TRANSFERRED TO ANY OTHER PERSON OR COMPANY WITHOUT THEIR CONSENT.
1) This inspection of the subject property shall be performed by the Inspector for the Client in accordance with the Standards of Practice of the Texas Real Estate Commission.
2) The purpose of this inspection is to identify and disclose visually observable major deficiencies of the inspected systems and items AT THE TIME OF THE INSPECTION ONLY. The inspector will not attempt to determine the life expectancy or future performance of any system or component. The inspector does not have x-ray vision and will not attempt to report on systems, items, or conditions that are not readily accessible. Roofs are walked on and crawl spaces are entered when conditions are such that allow us to do so safely and with reasonable effort. Detached structures are not included in the inspection unless specifically agreed upon by both the inspector and the client.
3) This inspection is not intended to be technically exhaustive nor is it considered to be a GUARANTEE OR WARRANTY, EXPRESSED OR IMPLIED, REGARDING THE CONDITIONS OF THE PROPERTY, ITEMS AND SYSTEMS INSPECTED AND IT SHOULD NOT BE RELIED ON AS SUCH. The Inspector shall not be held responsible or liable for any repairs or replacements with regard to this property, systems, components, or the contents therein. Company is neither a guarantor nor an insurer.
4) THE INSPECTION AND REPORT DO NOT ADDRESS AND ARE NOT INTENDED TO ADDRESS CODE AND REGULATION COMPLIANCE, THE POSSIBLE PRESENCE OF/OR DANGER FROM ASBESTOS, RADON GAS, LEAD PAINT, UREA FORMALDEHYDE, MOLD, FUNGUS, SOIL CONTAMINATION AND OTHER INDOOR AND OUTDOOR SUBSTANCES. THIS INSPECTOR IS NOT A STRUCTURAL ENGINEER. WHILE VISUAL OBSERVATIONS WILL BE MADE TO THE CONDITION OF THE FOUNDATION, EXACTING MEASUREMENTS OF PREVIOUS MOVEMENT AND/OR PREDICTIONS ABOUT FUTURE MOVEMENT ARE BEYOND THE SCOPE OF THIS INSPECTION. THE CLIENT IS URGED TO CONTACT A COMPETENT SPECIALIST IF FURTHER INFORMATION, IDENTIFICATION, OR TESTING OF THE ABOVE IS DESIRED.
5) IMAGES- The insertion of images in the written report are to perform as an aid to better understanding conditions or deficiencies  we have described in print. These images are inserted only as an example of conditions which may exist. The same or similar condition may exist in more than one area of the dwelling (wall cracks, foundation cracks, hail impacts, etc.) It is not practical, nor is it our intention to provide an image of every deficiency noted in the report or of every deficiency which may be present. The presence of an image should not be interpreted as being the only area this deficiency may exist.
We have only commented on deficiencies which we were aware of or felt were significant to the function or performance of the dwelling. We have not commented on items for which we were not aware of or on items which, in our opinion, were insignificant to the function or performance of the dwelling.

Page 2

6)Any matter concerning the interpretation of this Agreement, of the Inspection Report, or any claim based upon either of them shall be subject to mediation between the parties or failing such mediation shall be resolved by binding arbitration in accordance with the Construction Arbitration Services, Inc. Should such a need for mediation, arbitration and/or litigation arise, the inspector retains the right to collect all expenses incurred for defense, from the client or party, should the inspector be found innocent of negligence, errors or omissions.  THE INSPECTOR'S TOTAL LIMIT OF LIABILITY FOR ANY CLAIM BASED ON THIS AGREEMENT OR THE INSPECTION REPORT IS THE FEE CHARGED FOR THIS INSPECTION.  

7) Accurate Inspections will perform this inspection in accordance with the TREC standards of practice and provide as much information as could reasonably be expected, based on those standards. We will be direct and fair in our methods of inspecting, discussing and reporting. We expect our clients to be fair as well. If you have previous knowledge of the home or specific concerns, we expect that this information will be shared with the inspector. If a problem is present upon moving into the home that you feel should have been reported; we expect to be notified and allowed access to the property to inspect such problems prior to repairs being made, unless the situation is a true emergency. It is possible for undisclosed issues that were not apparent to the inspector to be discovered in the process of future repairs. Repair prior to closing will help reduce the possibility of unexpected expenses related to repairs.
8) Accurate Inspections is not responsible for another participant’s personal safety during this inspection process. Client, their representatives or others participation shall be at his/her own risk for falls, injuries, property damage, etc.
9) PLEASE NOTE: All Invoices are due and payable upon receipt unless prior arrangements have been made. Invoices delivered to the Title Company at your or your Agent's request are to be paid at the time of closing. If the contract does not go to closing, you hereby authorize the Title Company to pay this invoice from Escrow Funds on deposit. If there are insufficient Escrow funds available, you agree to submit payment outside of Escrow within 72 hours of the contract being cancelled. We do not carry accounts payable for more than 60 days. If your closing is more than 60 days from the date of this inspection, we request payment be made at time of the inspection.
The undersigned have read, understood and accepted the terms and conditions of this agreement and agree to pay Accurate Inspections ($Invoice) at or before the time of inspection, unless previous payment arrangements have been made.

In the absence of Client to sign this Inspection Agreement prior to or at the inspection or by authorizing your Realtor or agent to order, and/or accept this inspection on your behalf, this contract shall become part of the report.  Acceptance of the report, and/or payment for the inspection is an acknowledgement, acceptance, and agreement by Client(s) to the terms of this Inspection Agreement and limitations listed in the report and an acknowledgement the inspection includes only those items listed as inspected in the inspection report.
Accurate Inspections:                                                                              

_______________________________________                                                    
By: Randy Pounds, Texas Professional Inspector #20421

1 - Information

Weather Conditions
Clear
Temperature (approximate)
46 Fahrenheit (F)
Occupancy
Occupied
In Attendance
Buyer, Buyer's Agent, Inspector
Thank You

This report is confidential, for the Client's use only.  Thank you for choosing Accurate Inspections for your Structural and Mechanical inspection.

This inspection report is made for the sole purpose of assisting the purchaser to determine his and/or her own opinion of feasibility of purchasing the inspected property and does not warrant or guarantee all defects to be found. If you have any questions or are unclear regarding our findings, please call our office prior to expiration on any time limitations such as option periods.

This report contains technical information.  If you were not present during this inspection, please call the office or arrange for a consultation with your inspector.  If you choose not to consult with the inspector, this inspection company cannot be held liable for your understanding or misunderstanding of the reports content.

NOTE: The client walkthrough with the inspector is a synopsis of the more major issues noted during the inspection and is not meant to cover every aspect of the full inspection report.

This report is not intended to be used for determining insurability or warrantability of the structure and may not conform to the Texas Department of Insurance guidelines for property insurability.  This report is not to be used by or for any property and/or home warranty company.

The digital images in this report are a sample of the damages or deficiencies in place and should not be considered to show all of the damages and/or deficiencies found.  There will be some damage and/or deficiencies not represented with digital imaging.

The Client, by accepting this Property Inspection Report or relying upon it in any way, expressly agrees to the SCOPE OF INSPECTION, GENERAL LIMITATIONS and INSPECTION AGREEMENT included in this inspection report.



SCOPE 22 TAC 535.227(a) (1) These standards of practice apply when a professional inspector or real estate inspector who is licensed under this chapter accepts employment to perform a real estate inspection for a prospective buyer or seller of real property. (2) These standards of practice define the minimum requirements for a real estate inspection conducted on a one to four family unit that is substantially completed. Substantially completed means the stage of construction when a new building, addition, improvement, or alteration to an existing building can be occupied or used for its intended purpose . (3) For the purposes of these standards of practice a real estate inspection : (A) is a limited visual survey and basic performance evaluation of the systems and components of a building using normal controls that provides information regarding the general condition of a residence at the time of inspection; (B) is not intended to be a comprehensive investigation or exploratory probe to determine the cause or effect of deficiencies noted by the inspector; and (C) does not require the use of: (i) specialized equipment, including but not limited to : (I) thermal imaging equipment; (II) moisture meters; (III) gas or carbon monoxide detection equipment; (IV) environmental testing equipment and devices; (V) elevation determination devices; or (VI) ladders capable of reaching surfaces over one story above ground surfaces; or (ii) specialized procedures, including but not limited to: (I) environmental testing; (II) elevation measurement; (III) calculations; or (IV) any method employing destructive testing that damages otherwise sound materials or finishes. (4) These standards of practice do not prohibit an inspector from providing a higher level of inspection performance than required by these standards of practice or from inspecting components and systems in addition to those listed under the standards of practice. DEFINITIONS 22 TAC 535.227(b) (1) Accessible -In the reasonable judgment of the inspector, capable of being approached, entered, or viewed without: (A) hazard to the inspector; (B) having to climb over obstacles, moving furnishings or large, heavy, or fragile objects; (C) using specialized equipment or procedures; (D) disassembling items other than covers or panels intended to be removed for inspection; (E) damaging property, permanent construction or building finish; or (F) using a ladder for portions of the inspection other than the roof or attic space. (2) Chapter 1102 - Texas Occupations Code, Chapter 1102. (3) Component - A part of a system. (4) Cosmetic - Related only to appearance or aesthetics, and not related to performance, operability, or water penetration. (5) Deficiency - In the reasonable judgment of the inspector, a condition that: (A) adversely and materially affects the performance of a system, or component; or (B) constitutes a hazard to life, limb, or property as specified by these standards of practice. (6) Deficient--Reported as having one or more deficiencies. (7) Inspect - To operate in normal ranges using ordinary controls at typical settings, look at and examine accessible systems or components and report observed deficiencies as specified by these standards of practice. (8) Performance - Achievement of an operation, function or configuration relative to accepted industry standard practices with consideration of age and normal wear and tear from ordinary use. (9) Report - To provide the inspector's opinions and findings on the standard inspection report form as required by 535.222 and 535.223 of this title. (10)Standards of practice - 535.227 - 535.233 of this title. GENERAL REQUIREMENTS 22 TAC 535.227(c) The inspector shall: (1) operate fixed or installed equipment and appliances listed herein in at least one mode with ordinary controls at typical settings; (2) visually inspect accessible systems or components from near proximity to the systems and components, and from the interior of the attic and crawl spaces; and (3) complete the standard inspection report form as required by 535.222 and 535.223 of this title. GENERAL LIMITATIONS 22 TAC 535.227(d) The inspector is not required to: (1) inspect: (A) items other than those listed within these standards of practice; (B) elevators; (C) detached buildings, decks, docks, fences, or waterfront structures or related equipment; (D) anything buried, hidden, latent, or concealed; (E) sub-surface drainage systems; (F) automated or programmable control systems, automatic shut-off, photoelectric sensors, timers, clocks, metering devices, signal lights, lightning arrestor system, remote controls, security or data distribution systems, solar panels or smart home automation components; or (G) concrete flatwork such as driveways, sidewalks, walkways, paving stones or patios; (2) report: (A) past repairs that appear to be effective and workmanlike except as specifically required by these standards; (B) cosmetic or aesthetic conditions; or (C) wear and tear from ordinary use; (3) determine: (A) the presence or absence of pests, termites, or other wood-destroying insects or organisms; (B) the presence, absence, or risk of: (i) asbestos; (ii) lead-based paint; (iii) mold, mildew; (iv) corrosive or contaminated drywall "Chinese Drywall"; or (v) any other environmental hazard, environmental pathogen, carcinogen, toxin, mycotoxin, pollutant, fungal presence or activity, or poison; (C) types of wood or preservative treatment and fastener compatibility; or (D) the cause or source of a condition; (E) the cause or effect of deficiencies; (F) any of the following issues concerning a system or component: (i) insurability or warrantability; (ii) suitability, adequacy, compatibility, capacity, reliability, marketability, or operating costs; (iii) recalls, counterfeit products, or product lawsuits; (iv) life expectancy or age; (v) energy efficiency, vapor barriers, or thermostatic performance; (vi) compliance with any code, listing, testing or protocol authority; (vii) utility sources; or (viii)manufacturer or regulatory requirements, except as specifically required by these standards; (4) anticipate future events or conditions, including but not limited to: (A) decay, deterioration, or damage that may occur after the inspection; (B) deficiencies from abuse, misuse or lack of use; (C) changes in performance of any component or system due to changes in use or occupancy; (D) the consequences of the inspection or its effects on current or future buyers and sellers; (E) common household accidents, personal injury, or death; (F) the presence of water penetrations; or (G) future performance of any item; (5) operate shut-off, safety, stop, pressure or pressure-regulating valves or items requiring the use of codes, keys, combinations, or similar devices; (6) designate conditions as safe; (7) recommend or provide engineering, architectural, appraisal, mitigation, physical surveying, realty, or other specialist services; (8) review historical records, installation instructions, repair plans, cost estimates, disclosure documents, or other reports; (9) verify sizing, efficiency, or adequacy of the ground surface drainage system; (10) verify sizing, efficiency, or adequacy of the gutter and downspout system; (11) operate recirculation or sump pumps; (12) remedy conditions preventing inspection of any item; (13) apply open flame or light a pilot to operate any appliance; (14) turn on decommissioned equipment, systems or utility services; or (15) provide repair cost estimates, recommendations, or re-inspection services. CONFLICTS 22 TAC 535.227(e) In the event of a conflict between the general provisions set out in this section, and specific provisions specified elsewhere in the standards of practice, specific provisions shall take precedence. DEPARTURE PROVISION 22 TAC 535.227(f) (1) An inspector may depart from the inspection of a component or system required by the standards of practice only if: (A) the inspector and client agree the item is not to be inspected; (B) the inspector is not qualified to inspect the item; (C) in the reasonable judgment of the inspector, the inspector determines that: (i) conditions exist that prevent inspection of an item; (ii) conditions or materials are hazardous to the health or safety of the inspector; or (iii) the actions of the inspector may cause damage to the property (D) the item is a common element of a multifamily development and is not in physical contact with the unit being inspected, such as the foundation under another building or a part of the foundation under another unit in the same building. (2) If an inspector departs from the inspection of a component or system required by the standards of practice, the inspector shall: (A) notify the client at the earliest practical opportunity that the component or system will not be inspected; and (B) make an appropriate notation on the inspection report form, stating the reason the component or system was not inspected. (3) If the inspector routinely departs from inspection of a component or system required by the standards of practice, and the inspector has reason to believe that the property being inspected includes that component or system, the earliest practical opportunity for the notice required by this subsection is the first contact the inspector makes with the prospective client.  ENFORCEMENT 22 TAC 535.227(g) Enforcement. Failure to comply with the standards of practice is grounds for disciplinary action as prescribed by Chapter 1102.

2 - I. Structural Systems

IN NI NP D
2.1 A. Foundations X X
2.2 B. Grading and Drainage X X
2.3 C. Roof Covering Materials X X
2.4 D. Roof Structures and Attics X X
2.5 E. Walls (Interior and Exterior) X X
2.6 F. Ceilings and Floors X X
2.7 G. Doors (Interior and Exterior) X X
2.8 H. Windows X X
2.9 I. Stairways (Interior and Exterior) X
2.10 J. Fireplaces and Chimneys X X
2.11 K. Porches, Balconies, Decks, and Carports X X
A. Foundations: Type of Foundation(s)
Concrete Slab On Grade
D. Roof Structures and Attics: Viewed From
Entered the attic space
E. Walls (Interior and Exterior): Interior/Exterior Wall Type
EXTERIOR WALL TYPE:, Brick Veneer, Aluminum/Vinyl Siding, INTERIOR WALL TYPE:, Drywall



F. Ceilings and Floors: Interior Ceiling/Flooring Types
CEILING COVERING TYPE:, Blown acoustic ceiling covering, FLOOR COVERING TYPE:, Ceramic Tile, Carpet, Stained/Bare Concrete, Laminate



D. Roof Structures and Attics: Roof Structure Type
Gable Style Framing



D. Roof Structures and Attics: Insulation Depth/Type
6”-10”, Rolled Batt Type
A. Foundations: Not A Structural Engineer

The inspector is NOT a licensed structural engineer. If there are any concerns regarding movement and/or potential future movement of the foundation, we recommend that the client hire a professional engineer, licensed by the State of Texas, to perform a further evaluation and make any necessary recommendations in accordance with his/her findings. 

The foundation was assessed using the following criteria (lack or presence of): separation of frieze board corners, separation of brick veneer around doors/windows, separation of brick veneer around garage door trim, multiple & large brick veneer/mortar wall cracks, upheaval in flatwork/floors (i.e. garage floor, sidewalks, driveway, patios, interior tile floors, etc.), Interior cracks in the sheetrock around doors/windows, doors not operating properly and/or out of alignment, structural framing separation or cracks in framing members. (FYI: Soils in the North Texas area have a high clay and/or sand content. The soil expands and contracts based on varying rain amounts and drainage flow. The expansion & contraction of the soil inevitably results in some degree of movement or foundation distress over time.

The inspection may report the foundation to be functioning as designed, and/or in need of further evaluation or in need of possible repairs at the time of the inspection. The inspectors opinion does in no way warrant or guarantee the future performance or failure of the foundation. The opinion of the inspector is base upon a visual and cursory observations of the circumstances and condition at the day/time of the inspection.

A. Foundations: General Indications of Movement

GENERAL INDICATIONS OF TYPICAL STRUCTURAL MOVEMENT- Typical exterior brick fractures/mortar line separations, frieze board separation, minor misalignment of door frame(s), minor separations or openings between the exterior cladding and window and/or door frames, rafters pulling away from the attic ridgeboard, minor slopes in floors and typical cracks in walls and/or ceilings. It is common for existing structures to have some or all of the above mentioned items due to normal stress and soil related movement. If any part of this report is a concern, a Professional Engineer, of your choice, licensed in the State of Texas, should be consulted on integrity of the foundation and any repairs which may be necessary (if any).

B. Grading and Drainage: Graded Lot

The dwelling sits on a graded lot which appears to be above the height of the curbed street.  

C. Roof Covering Materials: Types of Roof Covering
3 Tab Composition and/or fiberglass shingles. Note: Average life expectancy under normal installation/conditions is between 10 -15 years.
C. Roof Covering Materials: Disclaimer

We always recommend that you confirm insurability with your prospective insuring agent PRIOR to closing.  
NOTE: Due to high roof damage claims, some insurance companies now require agents to physically observe the roof covering condition.
At their option, they may:
1. Accept the covering material in its current condition.
2. Require replacement in order for them to insure the roof material.
3. Exclude the roof covering and any consequential damage resulting from water penetration.
The inspector's opinion may or may not coincide with the insurance agents opinion. The inspection report may help the agent in his evaluation process. The inspector will not accept liability for any roof being rejected by an insurance company, as we are looking at the function of the roof in its current condition. The agent is looking to minimize risk.
Life expectancy of the roofing material is not covered by this inspection report.
The actual life of the roofing materials used can be influenced by external sources like; weather extremes, conditions caused by trees and vegetation and mechanical damage. If any concerns exist about the roof coverings life expectancy or potential for future problems, a roofing specialist should be consulted.

C. Roof Covering Materials: Gutters-Add

Gutters are not present at all roof slopes. Although they are not required, installation of gutters should be considered to help control surface water from possibly ponding around the structure/foundation.

E. Walls (Interior and Exterior): Caulk/Seal

Caulk, Grout or Sealant maybe needed in some areas around doors and/or window frames to help prevent moisture penetration of the exterior cladding.

E. Walls (Interior and Exterior): Previous Interior Repairs

There is evidence of painting/patching repairs to the interior wall surface finishes at one or more locations throughout the interior of the dwelling. This condition can limit the Inspectors visual observations and ability to render accurate opinions as to the performance of the structure.

F. Ceilings and Floors: Ceiling Previous Repairs

There is evidence of painting/patching repairs to the interior ceiling surface finishes at one or more locations throughout the interior of the dwelling. This condition can limit the Inspectors visual observations and ability to render accurate opinions as to the performance of the structure.

J. Fireplaces and Chimneys: Disclaimer

SPECIAL NOTE: The inspection of this/these fireplace(s) is a visual inspection only and is not a warranty and/or guarantee the fireplace(s), chimney(s) and termination cap(s) has/have been properly or safely installed/built.  No seismic damage assessments are made on the fireplace(s) This inspection is equivalent to a Level 1 inspection as described by the National Fire Protection Association (NFPA) If further evaluation is desired, we recommend a complete fireplace inspection by a qualified "Fireplace Inspector"

J. Fireplaces and Chimneys: Location/Type
Living Room, TYPE, Masonry w/Heat Form
K. Porches, Balconies, Decks, and Carports: Misc Porch, Carport, Deck, Balcony Photos
C. Roof Covering Materials: Viewed From
Observed by walking the roof surface where possible.
D. Roof Structures and Attics: Restricted

Not all parts of the attic are accessible.  Viewing/access was restricted by extreme high heat temperatures, low headroom (design of the structure), HVAC ductwork. stored items and/or the depth of the insulation blocking access. 

E. Walls (Interior and Exterior): Remodel

NOTE: The interior and/or exterior areas of this structure appears to have been freshly painted/remodeled. This condition may limit the inspectors visual observations and the true condition of the interior can be concealed. It is beyond the scope of this inspection to determine conditions below the surface of the paint.

E. Walls (Interior and Exterior): Stored Items

NOTE: Stored items and/or furnishings can prevent full inspection of all wall areas. Only visible surfaces, at the time of this inspection, were able to be seen/inspected. Some wall damage, moisture stains and/or cracks maybe evident after all furnishings are removed.

F. Ceilings and Floors: Flooring-Garage/Covered

We were unable to see some areas of the garage floor due to personal property covering the floor.

F. Ceilings and Floors: Remodel

NOTE: The interior of this structure appears to have been freshly painted/remodeled with areas of possible ceiling repairs being noted. This condition can limit the inspectors visual observations and the true condition of the interior can be concealed. It is beyond the scope of this inspection to determine conditions below the surface of the paint.

F. Ceilings and Floors: Stored Items

The condition of flooring is not determined where they are covered by carpets/rugs or other floor coverings, furniture and/or stored articles.

G. Doors (Interior and Exterior): Occupied/Limited

Due to the dwelling being occupied, full inspect/operation of some doors may be hampered/unable to be inspected, due to personal effects, large, heavy or fragile storage and/or furniture blocking these areas.

H. Windows: Occupied/Limited

Due to the dwelling being occupied, full inspect/operation of some windows may be hampered/unable to be inspected, due to window treatments, personal effects, large, heavy or fragile storage and/or furniture.

FOUNDATIONS 22 TAC 535.228(a) (1) The inspector shall: (A) render a written opinion as to the performance of the foundation; and (B) report: (i) the type of foundations; (ii) the vantage point from which the crawl space was inspected; (C) report present and visible indications of adverse performance of the foundation, such as: (i) binding, out-of-square, or non-latching doors; (ii) framing or frieze board separations; (iii) sloping floors; (iv) window, wall, floor, or ceiling cracks or separations; and (v) rotating, buckling, cracking, or deflecting masonry cladding. (D) report as Deficient: (i) deteriorated materials; (ii) deficiencies in foundation components such as; beams, joists, bridging, blocking, piers, posts, pilings, columns, sills or subfloor; (iii) deficiencies in retaining walls related to foundation performance; (iv) exposed or damaged reinforcement; (v) crawl space ventilation that is not performing; and (vi) crawl space drainage that is not performing. (2) The inspector is not required to: (A) enter a crawl space or any area where headroom is less than 18 inches or the access opening is less than 24 inches wide and 18 inches high; (B) provide an exhaustive list of indicators of possible adverse performance; or (C) inspect retaining walls not related to foundation performance.


GRADING AND DRAINAGE 22 TAC 535.228(b) (1) The inspector shall report as Deficient: (A) drainage around the foundation that is not performing; (B) deficiencies in grade levels around the foundation; and (C) deficiencies in installed gutter and downspout systems. (2) The inspector is not required to: (A) inspect flatwork or detention/retention ponds (except as related to slope and drainage); (B) determine area hydrology or the presence of underground water; or (C) determine the efficiency or performance of underground or surface drainage systems.


ROOF COVERING MATERIALS 22 TAC 535.228(c) (1) The inspector shall: (A) inspect the roof covering materials from the surface of the roof; (B) report: (i) type of roof coverings; (ii) vantage point from where the roof was inspected; (iii) evidence of water penetration; (iv) evidence of previous repairs to the roof covering material, flashing details, skylights and other roof penetrations; and (C) report as Deficient deficiencies in: (i) fasteners; (ii) adhesion; (iii) roof covering materials; (iv) flashing details; (v) skylights; and (vi) other roof penetrations. (2) The inspector is not required to: (A) inspect the roof from the roof level if, in the inspector's reasonable judgment, the inspector: (i) cannot safely reach or stay on the roof; or (ii) significant damage to the roof covering materials may result from walking on the roof; (B) determine: (i) the remaining life expectancy of the roof covering; or (ii) the number of layers of roof covering material; (C) identify latent hail damage; (D) exhaustively examine all fasteners and adhesion, or (E) provide an exhaustive list of locations of deficiencies and water penetrations.


ROOF STRUCTURES AND ATTICS 22 TAC 535.228(d) (1) The inspector shall: (A) report: (i) the vantage point from which the attic space was inspected; (ii) approximate average depth of attic insulation; (iii) evidence of water penetration; (B) report as Deficient: (i) attic space ventilation that is not performing; (ii) deflections or depressions in the roof surface as related to adverse performance of the framing and decking; (iii) missing insulation; (iv) deficiencies in (I) installed framing members and decking; (II) attic access ladders and access openings; and (III) attic ventilators. (2) The inspector is not required to: (A) enter attics or unfinished spaces where openings are less than 22 inches by 30 inches or headroom is less than 30 inches; (B) operate powered ventilators; or (C) provide an exhaustive list of locations of deficiencies and water penetrations.


INTERIOR WALLS, CEILINGS, FLOORS, AND DOORS 22 TAC 535.228(e) (1) The inspector shall: (A) report evidence of water penetration; (B) report as Deficient: (i) deficiencies in the condition and performance of doors and hardware; (ii) deficiencies related to structural performance or water penetration; and (iii) the absence of or deficiencies in fire separation between the garage and the living space and between the garage and its attic. (2) The inspector is not required to: (A) report cosmetic damage or the condition of floor, wall, or ceiling coverings; paints, stains, or other surface coatings; cabinets; or countertops, or (B) provide an exhaustive list of locations of deficiencies and water penetrations.


EXTERIOR WALLS, DOORS, AND WINDOWS 22 TAC 535.228(f) (1) The inspector shall: (A) report evidence of water penetration; (B) report as Deficient: (i) the absence of performing emergency escape and rescue openings in all sleeping rooms; (ii) a solid wood door less than 1-3/8 inches in thickness, a solid or honeycomb core steel door less than 1-3/8 inches thick, or a 20-minute fire-rated door between the residence and an attached garage; (iii) missing or damaged screens; (iv) deficiencies related to structural performance or water penetration; (v) deficiencies in: (I) weather stripping, gaskets or other air barrier materials; (II) claddings; (III) water resistant materials and coatings; (IV) flashing details and terminations; (V) the condition and performance of exterior doors, garage doors and hardware; and (VI) the condition and performance of windows and components. (2) The inspector is not required to: (A) report the condition of awnings, blinds, shutters, security devices, or other nonstructural systems; (B) determine the cosmetic condition of paints, stains, or other surface coatings; or (C) operate a lock if the key is not available. (D) provide an exhaustive list of locations of deficiencies and water penetrations.


EXTERIOR AND INTERIOR GLAZING 22 TAC 535.228(g) (1) The inspector shall report as Deficient: (A) insulated windows that are obviously fogged or display other evidence of broken seals; (B) deficiencies in glazing, weather stripping and glazing compound in windows and doors; and (C) the absence of safety glass in hazardous locations.(2) The inspector is not required to: (A) exhaustively inspect insulated windows for evidence of broken seals; (B) exhaustively inspect glazing for identifying labels; or (C) identify specific locations of damage.


INTERIOR AND EXTERIOR STAIRWAYS 22 TAC 535.228(h) (1) The inspector shall report as Deficient: (A) spacing between intermediate balusters, spindles, or rails for steps, stairways, guards, and railings that permit passage of an object greater than 4 inches in diameter, except that on the open side of the staircase treads, spheres less than 4-3/8 inches in diameter may pass through the guard rail balusters or spindles; and (B) deficiencies in steps, stairways, landings, guardrails, and handrails. (2) The inspector is not required to exhaustively measure every stairway component.


FIREPLACES AND CHIMNEYS 22 TAC 535.228(i) (1) The inspector shall report as Deficient: (A) built-up creosote in accessible areas of the firebox and flue; (B) the presence of combustible materials in near proximity to the firebox opening; (C) the absence of fireblocking at the attic penetration of the chimney flue, where accessible; and (D) deficiencies in the: (i) damper; (ii) lintel, hearth, hearth extension, and firebox; (iii) gas valve and location; (iv) circulating fan; (v) combustion air vents; and (vi) chimney structure, termination, coping, crown, caps, and spark arrestor. (2) The inspector is not required to: (A) verify the integrity of the flue; (B) perform a chimney smoke test; or (C) determine the adequacy of the draft.


PORCHES, BALCONIES, DECKS AND CARPORTS 22 TAC 535.228(j) (1) The inspector shall: (A) inspect: (i) attached balconies, carports, and porches; (ii) abutting porches, decks, and balconies that are used for ingress and egress; and (B) report as Deficient: (i) on decks 30 inches or higher above the adjacent grade, spacings between intermediate balusters, spindles, or rails that permit passage of an object greater than four inches in diameter; and (ii) deficiencies in accessible components. (2) The inspector is not required to: (A) exhaustively measure every porch, balcony, deck, or attached carport components; or (B) enter any area where headroom is less than 18 inches or the access opening is less than 24 inches wide and 18 inches high.



  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
$
Credit
Comment
2.1.1 - A. Foundations

Cracking/Chipping

Some cracking/chipping of the foundation and/or crawlspace perimeter stem wall was noted. This is very common and typically is not a structural concern. Shrinkage cracks can be sealed to prevent water/pest entry by filling the crack with masonry patching compound, epoxy, polyurethane foam and/or other sealants. 

Qualified Professional
$
Credit
Comment
2.1.2 - A. Foundations

Post Tension Cable

Some/all post tension cable end(s) have popped leaving exposed cable ends. Cable ends protruding from post-tension slabs should be covered with a concrete patch to prevent the cable ends from rusting. When rusting occurs, the cables grow thicker and eventually cause other foundation issues. We recommend that the ends be covered with a small concrete patch.

Qualified Professional
$
Credit
Comment
2.2.1 - B. Grading and Drainage

Driveway-Cracks Typical

Typical minor cracks in the concrete driveway were noted. Some cracking/chipping is a common occurrence due to the presence of expansive soils.

Driveway Contractor
$
Credit
Comment
2.2.2 - B. Grading and Drainage

Fence Deficiencies

The fence/gate around the yard, is in need of repairs. There are areas of damaged and/or missing components. If animal retention is required, we recommend that you carefully check for potential escape openings and the security of any gates and/or openings.

Fence Contractor
$
Credit
Comment
2.2.3 - B. Grading and Drainage

Pet Caused Erosion

There is what appears to be pet caused soil erosion against one or more areas of the foundation. Fill dirt maybe needed at these areas where the soil has been lost to properly help protect the foundation footing.

Handyman/DIY
$
Credit
Comment
2.3.1 - C. Roof Covering Materials

Fastener-Exposed

Roof fasteners (nails and/or staples) were observed to be exposed and should be properly sealed at one or more locations.

Roofing Professional
$
Credit
Comment
2.3.2 - C. Roof Covering Materials

Previous Repairs

Signs of prior repairs to the roofing material and/or flashing were observed in one or more locations. Inquire with sellers for details.

Inquire With Seller
$
Credit
Comment
2.3.3 - C. Roof Covering Materials

Sheathing-Soft/Spongy

Area(s) of soft/spongy sheathing was noted at one or more locations.

Qualified Professional
$
Credit
Comment
2.3.4 - C. Roof Covering Materials

Shingles-Not Sealed

A random sampling of shingles revealed that some of them and/or shingle corners were not properly bonded to the shingle layer below them. The "self sealing" capabilities of the shingle tabs may have failed allowing the shingles to be potentially lifted/damaged in strong winds.

Roofing Professional
$
Credit
Comment
2.3.5 - C. Roof Covering Materials

Starter Strip

The starter strip of the roofing material does not appear to be properly installed per the shingle manufacturers installation requirements.  The starter course shingle should consist of a strip shingle with the tabs cut off, with the self sealing strip at the lower edge. This will help prevent wind damage or lifting of the shingles in high wind conditions. Although this appears to be a generally accepted method of installation in our trade area, per the Texas Real Estate Commission Standards of Practice, we are required to report this as a deficiency.

$
Credit
Comment
2.3.6 - C. Roof Covering Materials

Tree-Damage

Damage from current and\or past tree limbs rubbing the surface of the roof material was observed.

Roofing Professional
$
Credit
Comment
2.4.1 - D. Roof Structures and Attics

Rafter-Split

Area(s) of rafter(s) are split and/or broken.

Qualified Professional
$
Credit
Comment
2.5.1 - E. Walls (Interior and Exterior)

Baseboard Damage

There is what appears to be moisture related stains/damage to some baseboards.

Qualified Professional
$
Credit
Comment
2.5.2 - E. Walls (Interior and Exterior)

Cladding/Frame Gap

There is a gap and/or repaired area between the window/door frame and the exterior cladding at one or more locations. This in an indication of likely structural movement at these locations.

Qualified Professional
$
Credit
Comment
2.5.3 - E. Walls (Interior and Exterior)

Flaking-Bathroom

The flaking and/or peeling of the wall covering in the bathroom, is generally signs of high humidity levels.

Qualified Professional
$
Credit
Comment
2.5.4 - E. Walls (Interior and Exterior)

Larger-Exterior Fractures

Larger step cracks and/or brick fractures are present in the exterior brick veneer. These types of cracks are typically influenced from movement in the structure and/or foundation at some point in time. If this is a concern, we recommend that you contact a reputable foundation repair company or a properly licensed Structural Engineer for further evaluation.

Foundation Contractor
$
Credit
Comment
2.5.5 - E. Walls (Interior and Exterior)

Stacked Bricks

Stacked bricks/personal items, etc. against an exterior wall were preventing full inspection of these areas.

Qualified Professional
$
Credit
Comment
2.5.6 - E. Walls (Interior and Exterior)

Typical Brick/Cinder Block Fractures

Typical mortar line step cracks, brick fractures/cinder block and/or mortar line separations are present in the exterior brick/cinder block veneer.  These types of cracks are common and are generally caused by expansion and contraction in the exterior veneer due to ever changing weather and soil conditions.

Qualified Professional
$
Credit
Comment
2.5.7 - E. Walls (Interior and Exterior)

Typical Drywall/Plaster Cracks

Typical drywall/plaster fractures, tape seam separations and/or repaired fractures were noted in some interior wall surfaces over/around doorways and/or windows at one or more locations around the structure. These are typically an indication of slight structural component movement and/or shrinkage of materials.

Drywall Contractor
$
Credit
Comment
2.5.8 - E. Walls (Interior and Exterior)

Spray Foam

Spary foam repairs were noted at one or more locations. 

Qualified Professional
$
Credit
Comment
2.5.9 - E. Walls (Interior and Exterior)

Kitchen Backsplash

The kitchen backsplash was noted with minor damage at one or more locations. 

Qualified Professional
$
Credit
Comment
2.6.1 - F. Ceilings and Floors

Carpet-Damage

Areas of carpet damage was noted.

Flooring Contractor
$
Credit
Comment
2.6.2 - F. Ceilings and Floors

Carpet-Stains

Carpet stains were noted at one or more locations.

Carpet Cleaner
$
Credit
Comment
2.6.3 - F. Ceilings and Floors

Ceiling-Sagging Drywall

Ceiling drywall sagged slightly the time of the inspection. 

Drywall Contractor
$
Credit
Comment
2.6.4 - F. Ceilings and Floors

Ceiling-Typical Cracks

Typical drywall/plaster fractures, tape seam separations and/or fracture repairs were noted in some interior ceiling surfaces at one or more locations around the structure. These are typically an indication of slight structural component movement or shrinkage of materials.

Drywall Contractor
$
Credit
Comment
2.6.5 - F. Ceilings and Floors

Ceiling-Wrinkles

The interior sheet rock tape and/or wall paper is pulling and twisting where the wall and ceiling intersect. This "wrinkling" is sometimes related to structural movement and should be further evaluated.

Qualified Professional
$
Credit
Comment
2.6.6 - F. Ceilings and Floors

Garage-Floor Typical

Typical stress/shrinkage fractures were present in the garage floor.

$
Credit
Comment
2.6.7 - F. Ceilings and Floors

Typical Concrete Cracks

Typical cracks were observed in the bare concrete flooring.

Qualified Professional
$
Credit
Comment
2.7.1 - G. Doors (Interior and Exterior)

Damaged/Missing Hardware

The door hardware is damaged/missing and/or is not functioning properly at one or more locations.

Handyman/DIY
$
Credit
Comment
2.7.2 - G. Doors (Interior and Exterior)

Door/Frame Damaged

Damaged door(s) and/or door frames were noted.

Qualified Professional
$
Credit
Comment
2.7.3 - G. Doors (Interior and Exterior)

Door-Stops Missing

Door stops are missing/damaged at one or more locations. These are needed to protect the walls from doorknob damage.

Handyman/DIY
$
Credit
Comment
2.7.4 - G. Doors (Interior and Exterior)

Garage Door-Weatherstrip

Garage door weatherstrip was noted as being damaged or missing.

Qualified Professional
$
Credit
Comment
2.7.5 - G. Doors (Interior and Exterior)

Not Latching

One or more doors were noted as not latching properly. The striker plates may need adjusting.

Handyman/DIY
$
Credit
Comment
2.7.6 - G. Doors (Interior and Exterior)

Pet Caused Damage

Pet caused damage was visible on the door, door frame and/or weather-strip.

Handyman/DIY
$
Credit
Comment
2.7.7 - G. Doors (Interior and Exterior)

Strike Plate Missing

Missing strike plates were noted at one or more locations.

Handyman/DIY
$
Credit
Comment
2.8.1 - H. Windows

Cracked/Broken/Chipped

Cracked/broken/chipped and/or missing window pane(s) were noted at one or more locations.

Window Repair and Installation Contractor
$
Credit
Comment
2.8.2 - H. Windows

Screen-Missing

One or more window screens were missing.

Window Repair and Installation Contractor
$
Credit
Comment
2.10.1 - J. Fireplaces and Chimneys

Cracks-In Replaceable

Minor cracks were noted in the replaceable firebrick inserts.

Qualified Professional
$
Credit
Comment
2.10.2 - J. Fireplaces and Chimneys

Creosote/Ash Build Up

A build up of creosote and/or ash was observed in the unit and/or chimney.

Chimney Sweep
$
Credit
Comment
2.10.3 - J. Fireplaces and Chimneys

Smoke Rollout

Smoke rollout soot was noted. This is typically caused when a flue is not opened during use.

Qualified Professional
$
Credit
Comment
2.11.1 - K. Porches, Balconies, Decks, and Carports

Porch-Typical Fractures

Typical stress/shrinkage fractures were present in visible areas of the porch floor.

Monitor

3 - II. Electrical Systems

IN NI NP D
3.1 A. Service Entrance and Panels X X
3.2 B. Branch Circuits, Connected Devices, and Fixtures X X
A. Service Entrance and Panels: Main Panel Amps
200
A. Service Entrance and Panels: Service Type
Electrical service is overhead.
B. Branch Circuits, Connected Devices, and Fixtures: Type of Wiring
Copper, Combination Of Grounded & Ungrounded
A. Service Entrance and Panels: Main Panel Location
Laundry Room/Closet
A. Service Entrance and Panels: Electrician

We recommend that a licensed electrician be contacted to further evaluate the deficiencies outlined in this report. 

A. Service Entrance and Panels: Federal Pacific

The main electrical service panel and its circuit breakers for this structure are Federal-Pacific "Stab-Lock" products. Federal-Pacific brand equipment was the most popular brand of electrical control equipment installed in structures in the 1960's thru the early 1980's. Most of this equipment is still in use today. There is wide spread information available which questions the reliability of this equipment. Full evaluation of this panel box is beyond the scope of this inspection. If this is a concern, we recommend further evaluation by a qualified licensed electrician of your choice.

B. Branch Circuits, Connected Devices, and Fixtures: Random Testing

A random testing was performed on the various outlets and switches, but NOT all were tested.  During a typical inspection there are many that are not accessible due to furnishings, storage, etc.  Light switches, ceiling fans, etc, which do not appear to function are typically deemed to have burned out bulbs and bulbs are not removed and checked, unless other anomalies are noticed. Also, some ceiling fans maybe operated with a remote control. Unless, the remote control is provided to the inspector, the fan may not be operated.

B. Branch Circuits, Connected Devices, and Fixtures: 3 Prong

Some of the electrical receptacles in the structure, have 3 prong receptacles improperly connected to older 2 wire ungrounded type wiring. This may give the first impression the wiring may have been updated, when only the receptacles have been changed. This arrangement does not provide the same protection as 3 wire grounded wiring.

B. Branch Circuits, Connected Devices, and Fixtures: Electrician

We recommend that a licensed electrician be contacted to further evaluate the deficiencies outlined in this report.

B. Branch Circuits, Connected Devices, and Fixtures: Smoke/CO² Security System

NOTE: Detectors appear to be built into the security system. Testing security systems is beyond the scope of a home inspection. We recommend checking with current owners about the functionality of this system.

SERVICE ENTRANCE AND PANELS 22 TAC 535.229 (a) (1) The inspector shall report as Deficient: (A) a drop, weatherhead or mast that is not securely fastened to the building; (B) the absence of or deficiencies in the grounding electrode system; (C) missing or damaged dead fronts or covers plates; (D) conductors not protected from the edges of electrical cabinets, gutters, or cutout boxes; (E) electrical cabinets and panel boards not appropriate for their location; such as a clothes closet, bathrooms or where they are exposed to physical damage; (F) electrical cabinets and panel boards that are not accessible or do not have a minimum of 36-inches of clearance in front of them; (G) deficiencies in: (i) electrical cabinets, gutters, cutout boxes, and panel boards; (ii) the insulation of the service entrance conductors, drip loop, separation of conductors at weatherheads, and clearances; (iii) the compatibility of overcurrent devices and conductors; (iv) the overcurrent device and circuit for labeled and listed 240 volt appliances; (v) bonding and grounding; (vi) conductors; (vii) the operation of installed ground-fault or arc-fault circuit interrupter devices; and (H) the absence of: (i) trip ties on 240 volt overcurrent devices or multi-wire branch circuit; (ii) appropriate connections; (iii) anti-oxidants on aluminum conductor terminations; (iv) a main disconnecting means. (2) The inspector is not required to: (A) determine present or future sufficiency of service capacity amperage, voltage, or the capacity of the electrical system; (B) test arc-fault circuit interrupter devices when the property is occupied or damage to personal property may result, in the inspector's reasonable judgment; (C) conduct voltage drop calculations; (D) determine the accuracy of overcurrent device labeling; (E) remove covers where hazardous as judged by the inspector; (F) verify the effectiveness of overcurrent devices; or (G) operate overcurrent devices.


BRANCH CIRCUITS, CONNECTED DEVICES, AND FIXTURES 22 TAC 535.229 (b) (1) The inspector shall: (A) manually test the installed and accessible smoke and carbon monoxide alarms; (B) report the type of branch circuit conductors; (C) report as Deficient: (i) the absence of ground-fault circuit interrupter protection in all: (I) bathroom receptacles; (II) garage receptacles; (III) outdoor receptacles; (IV) crawl space receptacles; (V) unfinished basement receptacles; (VI) kitchen countertop receptacles; and (VII)receptacles that are located within six feet of the outside edge of a sink; (ii) the failure of operation of ground-fault circuit interrupter protection devices; (iii) missing or damaged receptacle, switch or junction box covers; (iv) the absence of: (I) equipment disconnects; (II) appropriate connections, such as copper/aluminum approved devices, if branch circuit aluminum conductors are discovered in the main or sub-panel based on a random sampling of accessible receptacles and switches; (v) appliances and metal pipes that are not bonded or grounded; (vi) deficiencies in: (I) receptacles; (II) switches; (III) wiring, wiring terminations, junction boxes, devices, and fixtures, including improper location; (IV) doorbell and chime components; (V) smoke and carbon monoxide alarms; (vii) improper use of extension cords; (viii) deficiencies in or absences of conduit, where applicable; and \ (ix) the absence of smoke alarms: (I) in each sleeping room; (II) outside each separate sleeping area

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
$
Credit
Comment
3.1.1 - A. Service Entrance and Panels

GFCI/AFCI Breaker(s) Failed

One or more GFCI/AFCI breaker(s), in the electrical panel, failed to function properly.

Qualified Professional
$
Credit
Comment
3.1.2 - A. Service Entrance and Panels

Improper Wire Gauge

There is a 50 amp circuit breaker with what appears to be a 10 gauge wire connected to it. The minimum wire size for this breaker should be a 6 gauge. The potential danger of this condition could be that the wire insulation melting  because of the large amount of current flowing through it compared to how much the cables can handle and can become a potential fire hazard. Recommend further evaluation by a licensed electrician. 

Electrical Contractor
$
Credit
Comment
3.1.3 - A. Service Entrance and Panels

Labels

Not all of the breakers at the main panel and/or sub-panels are labeled properly. All circuits should be clearly marked so they can be shut down in case of an emergency.

DIY
$
Credit
Comment
3.2.1 - B. Branch Circuits, Connected Devices, and Fixtures

Ceiling Light/Fan-Chain Operation

One or more ceiling light/fan appeared to be controlled by the pull chains only. They did not respond to wall switches.

Qualified Professional
$
Credit
Comment
3.2.2 - B. Branch Circuits, Connected Devices, and Fixtures

Loose/Missing Fixture

A loose, damaged and/or missing fixture was noted.

Qualified Professional
$
Credit
Comment
3.2.3 - B. Branch Circuits, Connected Devices, and Fixtures

Receptacle-GFCI

Ground Fault Circuit Interrupter(s) were not present in accordance with current day electrical requirements at all applicable receptacle locations (within 6 feet of water sources). NOTE: These GFCI's may not have been required at the time this dwelling was constructed, however, per TREC guidelines, we are required to report this as a deficiency regardless of the dwelling construction date.

Electrical Contractor

4 - III. Heating, Ventilation and Air Conditioning Systems

IN NI NP D
4.1 A. Heating Equipment X
4.2 B. Cooling Equipment X X
4.3 C. Duct Systems, Chases, and Vents X
A. Heating Equipment: Heating Info

By: Trane

Manufactured in: Appears to be 1994

A. Heating Equipment: No significant heating equipment deficiencies were noted at the time of this inspection.
B. Cooling Equipment: Cooling Info

By: Trane

Manufactured in: 1993

3 Ton Unit

B. Cooling Equipment: Annual Cleaning

Condenser should be cleaned and serviced annually. 

B. Cooling Equipment: Type of Systems
Electric Split System
B. Cooling Equipment: Air Conditioner Disconnect Type
Pullout Type
C. Duct Systems, Chases, and Vents: Type of Ductwork
Combo-Metal and flexible ductwork
C. Duct Systems, Chases, and Vents: Location of Air filter
The air filter is located at the furnace cabinet.
A. Heating Equipment: Type of Systems
Electric Forced Air
A. Heating Equipment: Life Span

NOTE: Average life span of heating furnaces in this area typically range between 12-18 years, under normal conditions.

A. Heating Equipment: Heat Exchanger Evaluation

NOTE: Full evaluation of the integrity of a heat exchanger requires dismantling of the furnace and is beyond the scope of this inspection.

B. Cooling Equipment: Life Span

NOTE: Average life span of an A/C condenser unit in this area is typically between 10 - 12 years, under normal conditions. (slightly shorter for heat pumps).

B. Cooling Equipment: Differential OK

NOTE: Temperature differential readings are a fundamental standard for testing the proper operation of the cooling system. The normal acceptable range is considered between 15° and 20° Fahrenheit. This is the temperature difference between the return air and supply air readings. Unusual conditions, such as excessive humidity, low outdoor temperatures and/or restricted airflow can skew these readings to a point where a system may be functioning as designed and have abnormal air temperature differences or may indicate normal operation despite equipment malfunction. The temperature drop/differential observed at the time of this inspection was in the acceptable range.

HEATING EQUIPMENT 22 TAC 535.230(a) (1) General requirements. (A) The inspector shall report: (i) the type of heating systems; (ii) the energy sources; (B) The inspector shall report as Deficient: (i) inoperative units; (ii) deficiencies in the thermostats; (iii) inappropriate location; (iv) the lack of protection from physical damage; (v) burners, burner ignition devices or heating elements, switches, and thermostats that are not a minimum of 18 inches above the lowest garage floor elevation, unless the unit is listed for garage floor installation; (vi) the absence of an opening that would allow access to equipment for inspection, service, repair or replacement without removing permanent construction or building finish; (vii) when applicable; a floored passageway and service platform that would allow access for equipment inspection, service, repair or replacement; (viii) deficiencies in mounting and performance of window and wall units; (2) Requirements for electric heating units, the inspector shall report deficiencies in: (A) performance of heat pumps; (B) performance of heating elements; and (C) condition of conductors; and (3) Requirements for gas heating units, the inspector shall report as Deficient: (A) gas leaks; (B) flame impingement, uplifting flame, improper flame color, or excessive scale buildup; (C) the absence of a gas shut-off valve within six feet of the appliance; (D) the absence of a gas appliance connector or one that exceeds six feet in length; (E) gas appliance connectors that are concealed within or extended through walls, floors, partitions, ceilings or appliance housings; and (F) deficiencies in: (i) combustion, and dilution air; (ii) gas shut-off valves; (iii) access to a gas shutoff valves that prohibits full operation; (iv) gas appliance connector materials; and (v) the vent pipe, draft hood, draft, proximity to combustibles, and vent termination point and clearances; and COOLING EQUIPMENT 22 TAC 535.230(b) (1) Requirements for cooling units other than evaporative cooler. (A) The inspector shall report the type of systems; (B) The inspector shall report as Deficient: (i) inoperative units; (ii) inadequate cooling as demonstrated by its performance; (iii) the absence of an opening that would allow access to equipment for inspection, service, repair or replacement without removing permanent construction or building finish; (iv) when applicable; a floored passageway and service platform that would allow access for equipment inspection, service, repair or replacement; (v) noticeable vibration of blowers or fans; (vi) water in the auxiliary/secondary drain pan; (vii) a primary drain pipe that discharges in a sewer vent; (viii)missing or deficient refrigerant pipe insulation; (ix) dirty coils, where accessible; (x) condensing units lacking adequate clearances or air circulation or that has deficiencies in the fins, location, levelness, or elevation above grade surfaces; (xi) deficiencies in: (I) the condensate drain and auxiliary/ secondary pan and drain system; (II) mounting and performance of window or wall units; and (III) thermostats. (2) Requirements for evaporative coolers. (A) The inspector shall report: (i) type of systems; (ii) the type of water supply line; (B) The inspector shall report as Deficient: (i) inoperative units; (ii) inadequate access and clearances; (iii) deficiencies in performance or mounting; (iv) missing or damaged components; (v) the presence of active water leaks; and (vi) the absence of backflow prevention. DUCT SYSTEMS, CHASES, AND VENTS 22 TAC 535.230(c) (1) The inspector shall report as Deficient: (A) damaged duct systems or improper material; (B) damaged or missing duct insulation; (C) the absence of air flow at accessible supply registers; (D) the presence of gas piping and sewer vents concealed in ducts, plenums and chases; (E) ducts or plenums in contact with earth; and (2) The inspector shall report as Deficient deficiencies in: (A) filters; (B) grills or registers; and (C) the location of return air openings. GENERAL LIMITATIONS 22 TAC 535.230(d) For heating, ventilation, and air conditioning systems inspected under this section, the inspector is not required to perform the following actions: (1) program digital thermostats or controls; (2) inspect: (A) for pressure of the system refrigerant, type of refrigerant, or refrigerant leaks; (B) winterized or decommissioned equipment; or (C) duct fans, humidifiers, dehumidifiers, air purifiers, motorized dampers, electronic air filters, multi-stage controllers, sequencers, heat reclaimers, wood burning stoves, boilers, oil-fired units, supplemental heating appliances, de-icing provisions, or reversing valves; (3) operate: (A) setback features on thermostats or controls; (B) cooling equipment when the outdoor temperature is less than 60 degrees Fahrenheit; (C) radiant heaters, steam heat systems, or unvented gas-fired heating appliances; or (D) heat pumps, in the heat pump mode, when the outdoor temperature is above 70 degrees; (4) verify: (A) compatibility of components; (B) tonnage match of indoor coils and outside coils or condensing units; (C) the accuracy of thermostats; or (D) the integrity of the heat exchanger; or (5) determine: (A) sizing, efficiency, or adequacy of the system; (B) balanced air flow of the conditioned air to the various parts of the building; or (C) types of materials contained in insulation.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
$
Credit
Comment
4.2.1 - B. Cooling Equipment

Thermostat-Loose

The thermostat was noted being loose from the wall at the time of this inspection.

Qualified Professional
$
Credit
Comment
4.2.2 - B. Cooling Equipment

Vegetation

The foliage at and/or around the outside condenser/coils should be trimmed back a minimum of 18 inches to help improve air circulation.

Qualified Professional

5 - IV. Plumbing Systems

IN NI NP D
5.1 A. Plumbing Supply, Distribution Systems, and Fixtures X X
5.2 B. Drains, Wastes, and Vents X
5.3 C. Water Heating Equipment X X
5.4 D. Hydro-Massage Therapy Equipment X
5.5 F. Gas Distribution Systems and Gas Appliances X
C. Water Heating Equipment: Water Heater Info

Manufacture Date: 2014

By: Rheem 

C. Water Heating Equipment: Capacity
50 Gallons
F. Gas Distribution Systems and Gas Appliances: Location of Gas Meter
Not Present
F. Gas Distribution Systems and Gas Appliances: Type of Gas Distribution Piping Material
Not Present
C. Water Heating Equipment: Energy Sources
Electric
A. Plumbing Supply, Distribution Systems, and Fixtures: Comments

We attempt to evaluate drain pipes by checking every drain that has a functional fixture Only visible accessible waste lines are inspected. We are observing draining properties for proper drainage or blocked/slowing draining. However, this is not a conclusive test and only a video scan by a licensed professional through the drain line system can confirm actual condition of the system. NOTE: Leaks/blockage can occur at anytime and we can only comment on the conditions we find at the time of the inspection.   

A. Plumbing Supply, Distribution Systems, and Fixtures: Water Meter/Shutoff Valve Location

The water meter is located in the yard, near the street. The main water shut off valve is located at the water meter. Municipal service appears to be the primary water source. With the water supply from a Municipal supplier, we are assuming the water is potable.

A. Plumbing Supply, Distribution Systems, and Fixtures: Type of Supply Piping Material
Combination of Materials
A. Plumbing Supply, Distribution Systems, and Fixtures: Water Pressure
63

The rate of flow may be different at different outlets and at different times of the day. The optimum range for residential water pressure is 40 to 80 psi.

B. Drains, Wastes, and Vents: Type of Drain Piping Material
Combination of Materials
C. Water Heating Equipment: Annual Maintenance Flush Needed

Water heaters should be flushed annually to prevent sediment buildup and maintain efficiency. 


A. Plumbing Supply, Distribution Systems, and Fixtures: Washer Connection-Do Not Disconnect

We do not remove attached washing machine hoses. We do not operate washing machines which have personal items in them. In these cases, our inspection is limited to a visual inspection only.

B. Drains, Wastes, and Vents: Stored Items

Due to personal items stored below some sinks, we were unable to fully see/inspect all areas.

PLUMBING SYSTEMS 22 TAC 535.231(a) (1)The inspector shall: (A) report: (i) location of water meter; (ii) location of homeowners main water supply shutoff valve; and (iii) static water pressure; (B) report as Deficient: (i) the presence of active leaks; (ii) water pressure in excess of 80 PSI; (iii) the lack of a pressure reducing valve when the water pressure exceeds 80 PSI; (iv) the lack of an expansion tank at the water heater(s) when a pressure reducing valve is in place at the water supply line/system, unless the pressure reducing valve automatically allows for thermal expansion; (v) the absence of: (I) fixture shut-off valves; (II) dielectric unions, when applicable; (III) back-flow devices, anti-siphon devices, or air gaps at the flow end of fixtures; and (vi) deficiencies in: (I) water supply pipes and waste pipes; (II) the installation and termination of the vent system; (III) the performance of fixtures and faucets not connected to an appliance; (IV) water supply, as determined by viewing functional flow in two fixtures operated simultaneously; (V) fixture drain performance; (VI) orientation of hot and cold faucets; (VII) installed mechanical drain stops; (VIII) commodes, fixtures, showers, tubs, and enclosures; and (IX) the condition of the gas distribution system. (2) The inspector is not required to: (A) operate any main, branch, or shut-off valves; (B) operate or inspect sump pumps or waste ejector pumps; (C) verify the performance of: (i) the bathtub overflow; (ii) clothes washing machine drains or hose bibbs; or (iii) floor drains; (D) inspect: (i) any system that has been winterized, shut down or otherwise secured; (ii) circulating pumps, free-standing appliances, solar water heating systems, waterconditioning equipment, filter systems, water mains, private water supply systems, water wells, pressure tanks, sprinkler systems, swimming pools, or fire sprinkler systems; (iii) inaccessible gas supply system components for leaks; (iv) for sewer clean-outs; or (v) for the presence or performance of private sewage disposal systems; or (E) determine: (i) quality, potability, or volume of the water supply; or (ii) effectiveness of backflow or antisiphon devices. WATER HEATERS 22 TAC 535.231(b) (1) General requirements. (A) The inspector shall: (i) report: (I) the energy source; (II) the capacity of the units; (ii) report as Deficient: (I) inoperative units; (II) leaking or corroded fittings or tanks; (III) damaged or missing components; (IV) the absence of a cold water shutoff valve; (V) if applicable, the absence of a pan or a pan drain system that does not terminate over a waste receptor or to the exterior of the building above the ground surface; (VI) inappropriate locations; (VII) the lack of protection from physical damage; (VIII) burners, burner ignition devices or heating elements, switches, or thermostats that are not a minimum of 18 inches above the lowest garage floor elevation, unless the unit is listed for garage floor installation; (IX) the absence of an opening that would allow access to equipment for inspection, service, repair or replacement without removing permanent construction or building finish; (X) when applicable; a floored passageway and service platform that would allow access for equipment inspection, service, repair or replacement; (XI) the absence of or deficiencies in the temperature and pressure relief valve and discharge piping; (XII) a temperature and pressure relief valve that failed to operate, when tested manually; (B) The inspector is not required to: (i) verify the effectiveness of the temperature and pressure relief valve, discharge piping, or pan drain pipes; (ii) operate the temperature and pressure relief valve if the operation of the valve may, in the inspector's reasonable judgment, cause damage to persons or property; or (iii) determine the efficiency or adequacy of the unit. (2) Requirements for electric units, the inspector shall report deficiencies in: (A) performance of heating elements; and (B) condition of conductors; and (3) Requirements for gas units, the inspector shall report as Deficient: (A) gas leaks; (B) flame impingement, uplifting flame, improper flame color, or excessive scale build-up; (C) the absence of a gas shut-off valve within six feet of the appliance; (D) the absence of a gas appliance connector or one that exceeds six feet in length; (E) gas appliance connectors that are concealed within or extended through walls, floors, partitions, ceilings or appliance housings; (F) deficiencies in: (i) combustion and dilution air; (ii) gas shut-off valves; (iii) access to a gas shutoff valves that prohibit full operation; (iv) gas appliance connector materials; and (v) vent pipe, draft hood, draft, proximity to combustibles, and vent termination point and clearances. HYDRO-MASSAGE THERAPY EQUIPMENT 22 TAC 535.231(c) (1) The inspector shall report as Deficient: (A) inoperative units; (B) the presence of active leaks; (C) deficiencies in components and performance; (D) missing and damaged components; (E) the absence of an opening that would allow access to equipment for inspection, service, repair or replacement without removing permanent construction or building finish; and (F) the absence or failure of operation of ground-fault circuit interrupter protection devices; and (2) The inspector is not required to determine the adequacy of self-draining features of circulation systems.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
$
Credit
Comment
5.1.1 - A. Plumbing Supply, Distribution Systems, and Fixtures

Anti-Siphon Missing

No anti-siphon protection was observed on one or more of the exterior hose bibs/faucets. This is an inexpensive basic safety device that attaches to the end of the faucet. These can be purchased at most home supply stores. This item will protect from a cross connection or back-flow of water into the house and is standard equipment on newer homes.

Qualified Professional
$
Credit
Comment
5.1.2 - A. Plumbing Supply, Distribution Systems, and Fixtures

Enclosure-Caulking/Grout
Master Bathroom

The caulking/grout needs attention.

Handyman/DIY
$
Credit
Comment
5.1.3 - A. Plumbing Supply, Distribution Systems, and Fixtures

Sprayer-Damaged

The sprayer handle was damaged/missing.

Qualified Professional
$
Credit
Comment
5.1.4 - A. Plumbing Supply, Distribution Systems, and Fixtures

Washer Connection-Corrosion

Some corrosion was present on some of the supply line fittings indicating a leak at some point in time. No leak was noted at the time of this inspection.

Monitor
$
Credit
Comment
5.3.1 - C. Water Heating Equipment

Corrosion/Rust

Some corrosion/rust was present on the water heater supply line and/or fittings indicating a leak at some point in time. No leak was noted at the time of this inspection.

Monitor

6 - V. Appliances

IN NI NP D
6.1 A. Dishwashers X X
6.2 B. Food Waste Disposers X X
6.3 C. Range Hood and Exhaust Systems X X
6.4 D. Ranges, Cooktops, and Ovens X X
6.5 E. Microwave Ovens X X
6.6 F. Mechanical Exhaust Vents and Bathroom Heaters X
6.7 G. Garage Door Operators X
6.8 H. Dryer Exhaust Systems X X
6.9 Trash Compactor X
6.10 Ice Maker X
F. Mechanical Exhaust Vents and Bathroom Heaters: No significant deficiencies were noted at the time of this inspection.
A. Dishwashers: Misc Dishwasher Photos
B. Food Waste Disposers: Misc Food Waste Disposer Photos
C. Range Hood and Exhaust Systems: Type
Recirculating
E. Microwave Ovens: Misc Microwave Photos
D. Ranges, Cooktops, and Ovens: Range/Oven Types
Electric
F. Mechanical Exhaust Vents and Bathroom Heaters: Misc Exhaust Vent Photos

GENERAL PROVISIONS 22 TAC 535.232(a) The inspector is not required to: (1) operate or determine the condition of other auxiliary components of inspected items; (2) test for microwave oven radiation leaks; (3) inspect self-cleaning functions; (4) disassemble appliances; (5) determine the adequacy of venting systems; or (6) determine proper routing and lengths of duct systems. DISHWASHERS 22 TAC 535.232(b) The inspector shall report as Deficient: (1) inoperative units; (2) deficiencies in performance or mounting; (3) rusted, missing or damaged components; (4) the presence of active water leaks; and (5) the absence of backflow prevention. FOOD WASTE DISPOSERS 22 TAC 535.232(c) The inspector shall report as Deficient: (1) inoperative units; (2) deficiencies in performance or mounting; (3) missing or damaged components; and (4) the presence of active water leaks. RANGE HOODS AND EXHAUST SYSTEMS 22 TAC 535.232(d) The inspector shall report as Deficient: (1) inoperative units; (2) deficiencies in performance or mounting; (3) missing or damaged components; (4) ducts that do not terminate outside the building, if the unit is not of a re-circulating type or configuration; and (5) improper duct material.  ELECTRIC OR GAS RANGES, COOKTOPS, AND OVENS 22 TAC 535.232(e) The inspector shall report as Deficient: (1) inoperative units; (2) missing or damaged components; (3) combustible material within thirty inches above the cook top burners; (4) absence of an anti-tip device, if applicable; (5) gas leaks; (6) the absence of a gas shutoff valve within six feet of the appliance; (7) the absence of a gas appliance connector or one that exceeds six feet in length; (8) gas appliance connectors that are concealed within or extended through walls, floors, partitions, ceilings or appliance housings; (9) deficiencies in: (A) thermostat accuracy (within 25 degrees at a setting of 350 F); (B) mounting and performance; (C) gas shut-off valves; (D) access to a gas shutoff valves that prohibits full operation; and (E) gas appliance connector materials. MICROWAVE OVENS 22 TAC 535.232(f) The inspector shall inspect built-in units and report as Deficient: (1) inoperative units; (2) deficiencies in performance or mounting; and (3) missing or damaged components. MECHANICAL EXHAUST SYSTEMS AND BATHROOM HEATERS 22 TAC 535.232(g) The inspector shall report as Deficient: (1) inoperative units; (2) deficiencies in performance or mounting; (3) missing or damaged components; (4) ducts that do not terminate outside the building; and (5) a gas heater that is not vented to the exterior of the building unless the unit is listed as an unvented type.  GARAGE DOOR OPERATORS 22 TAC 535.232(h) The inspector shall report as Deficient: (1) inoperative units; (2) deficiencies in performance or mounting; (3) missing or damaged components; (4) installed photoelectric sensors located more than six inches above the garage floor; and (5) door locks or side ropes that have not been removed or disabled.  DRYER EXHAUST SYSTEMS 22 TAC 535.232(i) The inspector shall report as Deficient: (1) missing or damaged components; (2) the absence of a dryer exhaust system when provisions are present for a dryer; (3) ducts that do not terminate to the outside of the building; (4) screened terminations; and (5) ducts that are not made of metal with a smooth interior finish.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
$
Credit
Comment
6.1.1 - A. Dishwashers

Rust/Corrosion

Minor rust and/or corrosion was observed in the unit/on the racks.

$
Credit
Comment
6.1.2 - A. Dishwashers

Hits Countertop

The door was noted hitting the countertop.

Qualified Professional
$
Credit
Comment
6.2.1 - B. Food Waste Disposers

No Wire Clamp

There is no stabilizing clamp where the power cord enters the disposer housing.

Handyman/DIY
$
Credit
Comment
6.3.1 - C. Range Hood and Exhaust Systems

Lights Failed

The light(s) at the range hood failed to function at the time of the inspection. It maybe just a simple case of burned out bulbs.

Qualified Professional
$
Credit
Comment
6.4.1 - D. Ranges, Cooktops, and Ovens

Light-Failed

The oven light failed to function at the time of the inspection. 

Qualified Professional
$
Credit
Comment
6.5.1 - E. Microwave Ovens

Damaged Door Handle

The door handle was damaged.

Qualified Professional
$
Credit
Comment
6.8.1 - H. Dryer Exhaust Systems

Termination-Attic

The dryer vent appeared to improperly terminate into the attic space. This is considered a potential fire hazard. This is not a normally accepted installation. Under current installation standards, the dryer vent is required to exhaust to the outside of the structure, not into the attic. However, venting into the attic appeared to be a generally accepted method of installation in this trade area at the time this structure was built. However, per the Texas Real Estate Commission Standards of Practice, we are required to report this as a deficiency.

Qualified Professional

7 - VI. Optional Systems

IN NI NP D
7.1 C. Outbuildings X
C. Outbuildings: There was not an order for the outbuilding to be inspected.

LIMITATIONS 22 TAC 535.233(a) An inspector is not required to inspect the components or systems described under this section.  SCOPE 22 TAC 535.233(b) If an inspector agrees to inspect a component or system described under this section, the general provisions under 535.227 and the provisions and requirements of this section applicable to that system or component apply. LANDSCAPE IRRIGATION (SPRINKLER) SYSTEMS 22 TAC 535.233(c) (1) The inspector shall: (A) manually operate all zones or stations on the system through the controller; (B) report as Deficient: (i) the absence of a rain or moisture sensor, (ii) inoperative zone valves; (iii) surface water leaks; (iv) the absence of a backflow prevention device; (v) the absence of shut-off valves between the water meter and backflow device; (vi) deficiencies in the performance and mounting of the controller; (vii) missing or damaged components; and (viii)deficiencies in the performance of the water emission devices; such as, sprayer heads, rotary sprinkler heads, bubblers or drip lines. (2) The inspector is not required to inspect: (A) for effective coverage of the irrigation system; (B) the automatic function of the controller; (C) the effectiveness of the sensors; such as, rain, moisture, wind, flow or freeze sensors; or (D) sizing and effectiveness of backflow prevention device. SWIMMING POOLS, SPAS, HOT TUBS, AND EQUIPMENT 22 TAC 535.233(d) (1) The inspector shall: (A) report the type of construction; (B) report as Deficient: (i) the presence of a single blockable main drain (potential entrapment hazard); (ii) a pump motor, blower, or other electrical equipment that lacks bonding; (iii) the absence of or deficiencies in safety barriers; (iv) water leaks in above-ground pipes and equipment; (v) the absence or failure in performance of ground-fault circuit interrupter protection devices; and (vi) deficiencies in: (I) surfaces; (II) tiles, coping, and decks; (III) slides, steps, diving boards, handrails, and other equipment; (IV) drains, skimmers, and valves; (V) filters, gauges, pumps, motors, controls, and sweeps; (VI) lighting fixtures; and (VII) the pool heater that these standards of practice require to be reported for the heating system. (2) The inspector is not required to: (A) disassemble filters or dismantle or otherwise open any components or lines; (B) operate valves; (C) uncover or excavate any lines or concealed components of the system; (D) fill the pool, spa, or hot tub with water; (E) inspect any system that has been winterized, shut down, or otherwise secured; (F) determine the presence of sub-surface water tables; (G) determine the effectiveness of entrapment covers; (H) determine the presence of pool shell or sub-surface leaks; or (I) inspect ancillary equipment such as computer controls, covers, chlorinators or other chemical dispensers, or water ionization devices or conditioners other than required by this section.  OUTBUILDINGS 22 TAC 535.233(e) (1) The inspector shall report as Deficient the absence or failure in performance of ground-fault circuit interrupter protection devices in gradelevel portions of unfinished accessory buildings used for storage or work areas, boathouses, and boat hoists; and (2) The inspector shall report as Deficient deficiencies in the structural, electrical, plumbing, heating, ventilation, and cooling systems that these standards of practice require to be reported for the principal building. PRIVATE WATER WELLS 22 TAC 535.233(f) (1) The inspector shall: (A) operate at least two fixtures simultaneously; (B) recommend or arrange to have performed coliform testing; (C) report: (i) the type of pump and storage equipment; (ii) the proximity of any known septic system; (D) report as Deficient deficiencies in: (i) water pressure and flow and performance of pressure switches; (ii) the condition of accessible equipment and components; and (iii) the well head, including improper site drainage and clearances. (2) The inspector is not required to: (A) open, uncover, or remove the pump, heads, screens, lines, or other components of the system; (B) determine the reliability of the water supply or source; or (C) locate or verify underground water leaks. PRIVATE SEWAGE DISPOSAL (SEPTIC) SYSTEMS. 22 TAC 535.233(g) (1) The inspector shall: (A) report: (i) the type of system; (ii) the location of the drain or distribution field; (iii) the proximity of any known water wells, underground cisterns, water supply lines, bodies of water, sharp slopes or breaks, easement lines, property lines, soil absorption systems, swimming pools, or sprinkler systems; (B) report as Deficient: (i) visual or olfactory evidence of effluent seepage or flow at the surface of the ground; (ii) inoperative aerators or dosing pumps; and (iii) deficiencies in: (I) accessible components; (II) functional flow; (III) site drainage and clearances around or adjacent to the system; and (IV) the aerobic discharge system. (2) The inspector is not required to: (A) excavate or uncover the system or its components; (B) determine the size, adequacy, or efficiency of the system; or (C) determine the type of construction used.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency