Repair Request List

1467 Cottonwood Rd
05/28/2024 12:23 pm

All bird damage has been repaired. 


3.5.2 - Exterior: Exterior Siding Notes
Past repairs
Cosmetic - Monitor - Maintenance

Recent or past repairs to the exterior siding was observed. We could not determine the reason for the repairs and recommend asking the seller about repairs and why they were needed.

Old patch was cleaned up as of 5/29

Location

Front

Original Inspection 4/23
Repaired as of 5/29

Repaired.

3.5.3 - Exterior: Exterior Siding Notes
Portions of siding missing
Cosmetic - Monitor - Maintenance

Portions of the siding are missing. Recommend repairs.

Repair was done as of 5/29.

Location

Rear

Original Inspection 4/23
Repaired as of 5/29

Repaired

3.7.1 - Exterior: Fascia, Trim & Eaves
Gaps
Cosmetic - Monitor - Maintenance

One or more gaps were observed. Recommend sealing to prevent pest access.

Repair was made as of 5/29

Location

Front

Original Inspection 4/23
Repaired as of 5/29

Replaced

3.11.1 - Exterior: Doorbell
Button is damaged or missing
Cosmetic - Monitor - Maintenance

The doorbell button is damaged or missing. You may want to have it replaced.

Repaired as of 5/29

Location

Front & Rear

Original Inspection 4/23
Original Inspection 4/23
Repaired as of 5/29
Repaired as of 5/29

All new flood lights installed

3.14.1 - Exterior: Lights
Light bulbs missing or burnt out
Cosmetic - Monitor - Maintenance

Some lights around the residence did not have light bulbs or the bulbs were burnt out. Recommend replacing bulbs and testing.

Repaired as of 5/29

Location

Front

Original Inspection 4/23
Repaired as of 5/29

All new garage doors installed

5.2.1 - Garage(s): Automatic Opener
Garage door opener did not work as intended
Cosmetic - Monitor - Maintenance

The garage door opener does not work as intended. Recommend repair.

Repaired as of 5/29

Original Inspection 4/23
Repaired as of 5/29

All new garage doors installed

5.3.1 - Garage(s): Garage Door & Hardware
Garage door cosmetic damage
Cosmetic - Monitor - Maintenance

The main garage door is functional, but has cosmetic damage. Recommend repair as needed.

Repaired as of 5/29

Original Inspection 4/23
Original Inspection 4/23
Repaired as of 5/29
Repaired as of 5/29

Still need to add a self closing hinge

5.4.1 - Garage(s): Entry Door Into the House
Home entry not self closing
Cosmetic - Monitor - Maintenance

The house garage entry door is functional but does not self-close. This may not have been required when the house was built and you may elect to have self closing hinges installed for modern fire safety.


Cover plate installed

5.13.1 - Garage(s): Outlets, Electrical Observations
Coverplate missing/damaged
Cosmetic - Monitor - Maintenance

Coverplates were missing on outlets, switches or junction boxes. Recommend installing cover plates.

Repaired as of 5/29

Original Inspection 4/23
Repaired as of 5/29

There was a leak, but that has been addressed and repaired by Weddle & Sons Roofing

7.3.1 - Attic: Roof Decking Notes
moisture stains on the underside decking
Cosmetic - Monitor - Maintenance

There are moisture stains on the underside of some wood decking. Recommend monitoring.

Old stain is still visible but no current moisture as of return visit 5/29 even with current rainfall. 

Original Inspection 4/23
Reinspection 5/29

All registers have been replaced if missing

8.8.1 - Heating System: Registers
registers missing
Cosmetic - Monitor - Maintenance

One or more register is missing. Recommend installing.

Repaired as of 5/29

Location

2nd Floor Powder Bathroom

Original Inspection 4/23
Repaired as of 5/29

Leak addressed and tightened

10.2.1 - Kitchen: Trap and Drain
leak at drain line below the sink
Cosmetic - Monitor - Maintenance

There is a leak at the drain line below the sink. Recommend repair.

Repaired as of 5/29

Please visit our Trusted Resources page for a list of contractors who can assist with this.

Location

2nd Floor Kitchenette

Original Inspection 4/23
Repaired as of 5/29

Repaired

12.2.1 - Bathrooms: Trap and Drain
Slow Drain
Cosmetic - Monitor - Maintenance

The sink drains slowly. Recommend repair.

Repaired as of 5/29

Location

Master Bathroom

Original Inspection 4/23
Repaired as of 5/29

Caulking was performed

12.4.3 - Bathrooms: Tub-Shower
Caulking or sealing
Cosmetic - Monitor - Maintenance

Gaps or opensings are observed around shower valves and fauct. Recommend sealing.





Location

1st Floor Bathroom


Handle needs to be turned the other direction

12.4.4 - Bathrooms: Tub-Shower
No hot water supply
Repair - Replace - Not Working

There is no hot water supply at the tub-shower faucet.  There is cold water supply, but when the handle is turned to the left or hot side, the water supply stops. Recommend further evaluation & repair.

Location

Master Bathroom


Toilet has been thoroughly cleaned. No evidence of leaking

12.5.1 - Bathrooms: Toilet
Staining Around Toilet
Cosmetic - Monitor - Maintenance

Staining and lifted flooring was observed around the base of the toilet. Recommend further evaluation.

Repaired as of 5/29

Location

Master Bathroom

Original Inspection 4/23
Repaired as of 5/29

Professional carpet cleaners have cleaned the areas of concern

14.4.1 - Interior: Flooring
Carpet is stained
Cosmetic - Monitor - Maintenance

The carpet is stained. Recommend a thorough cleaning or replacement as needed.

Improvements made as of 5/29

Location

Several Areas Throughout

Original Inspection 4/23
Original Inspection 4/23
Original Inspection 4/23
Original Inspection 4/23
Improvements made as of 5/29

New carpet has been installed

14.4.2 - Interior: Flooring
Carpet/flooring removed
Cosmetic - Monitor - Maintenance

The flooring was removed. Recommend installing.

Repaired as of 5/29

Location

Throughout 1st Floor

Original Inspection 4/23
Original Inspection 4/23
Original Inspection 4/23
Original Inspection 4/23
Repaired as of 5/29

Sheetrock has been repaired

14.5.3 - Interior: Walls and Ceiling
Evidence of moisture intrusion
Cosmetic - Monitor - Maintenance

There is evidence of moisture intrusion. Recommend further evaluation and repair as needed.

Repaired as of 5/29

Location

1st Floor Rear Bedroom Closet

Original Inspection 4/23
Repaired as of 5/29

Sheetrock has been repaired

14.5.4 - Interior: Walls and Ceiling
Patch/past repair
Cosmetic - Monitor - Maintenance

Patches or repairs were observed in the wall or ceiling. We could not determine the reason for the repairs. Recommend monitoring.

Improvement made as of 5/29

Location

Several Throughout

Original Inspection 4/23
Original Inspection 4/23
Original Inspection 4/23
Improvement made as of 5/29
Improvement made as of 5/29
Improvement made as of 5/29

Cover plate installed

14.13.1 - Interior: Outlets, Electrical
Missing / damaged covers
Cosmetic - Monitor - Maintenance

There were missing / damaged covers that should be installed

Location

Master Bathroom